Literature DB >> 10548205

Temperature measurement in critically ill orally intubated adults: a comparison of pulmonary artery core, tympanic, and oral methods.

K K Giuliano1, S S Scott, S Elliot, A J Giuliano.   

Abstract

OBJECTIVE: Core temperature measurement using a pulmonary artery (PA) catheter is considered the gold standard for measuring temperatures in critically ill patients. The objective of this study was to compare oral and tympanic temperature measurements (in both the oral and core equivalence modes) against PA core temperature measurements to determine which method was the most accurate and reliable in the absence of a PA catheter.
DESIGN: Prospective, descriptive comparative analysis. PATIENTS: Convenience sample of 102 critically ill orally intubated patients with a PA catheter in place.
SETTING: A 24-bed medical/surgical/trauma intensive care unit in a university-affiliated medical center.
INTERVENTIONS: Four experienced intensive care unit nurses were trained in the use of temperature measurement with the oral, tympanic (both core and oral equivalence modes were used), and PA core methods. Simultaneous temperature measurements were then taken once in each subject using each method. The potential covariates that were analyzed were mean blood pressure, patient acuity using the Simplified Acute Physiology Score II, age, sex, ambient room temperature, and ventilator circuit temperature.
MEASUREMENTS AND MAIN RESULTS: The training period indicated that it took more time to train experienced nurses in the use of tympanic thermometry than oral thermometry. Descriptive statistics were the following: core, x = 37.33 (SD = 0.89); oral, x = 37.18 (SD = 0.92); tympanic oral, x = 36.80 (SD = 0.93); and tympanic core, x = 37.12 (SD = 1.0). Bias averages were calculated and were significantly different from 0 for all three methods (oral-PA core, -0.15 [SD = 0.36]; tympanic core-PA core, -0.11 [SD = 0.57], tympanic oral-PA core, -0.52 [SD = 0.53]), indicating that there is some degree of decreased accuracy associated with each method when compared with PA core. However, scatter plots using the Bland and Altman methodology (Altman DG, Bland JM: Practical Statistics for Medical Research. London, Chapman and Hall, 1991) illustrate that the greatest variability is associated with the tympanic method.
CONCLUSIONS: Temperature measurement is an important piece of clinical data in a critically ill patient population. We found oral thermometry to be the most accurate and reproducible method when a PA core measurement was not available.

Entities:  

Mesh:

Year:  1999        PMID: 10548205     DOI: 10.1097/00003246-199910000-00020

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  14 in total

Review 1.  Critical care in the emergency department: monitoring the critically ill patient.

Authors:  F J Andrews; J P Nolan
Journal:  Emerg Med J       Date:  2006-07       Impact factor: 2.740

Review 2.  Thermometry in paediatric practice.

Authors:  A S El-Radhi; W Barry
Journal:  Arch Dis Child       Date:  2006-04       Impact factor: 3.791

Review 3.  Design, analysis, and interpretation of method-comparison studies.

Authors:  Sandra K Hanneman
Journal:  AACN Adv Crit Care       Date:  2008 Apr-Jun

4.  Reproducibility of physiological track-and-trigger warning systems for identifying at-risk patients on the ward.

Authors:  Christian P Subbe; Haiyan Gao; David A Harrison
Journal:  Intensive Care Med       Date:  2007-01-18       Impact factor: 17.440

5.  Temperature measurement in intensive care patients: comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core method.

Authors:  J-Y Lefrant; L Muller; J Emmanuel de La Coussaye; M Benbabaali; C Lebris; N Zeitoun; C Mari; G Saïssi; J Ripart; J-J Eledjam
Journal:  Intensive Care Med       Date:  2003-02-08       Impact factor: 17.440

6.  Oral and tympanic membrane temperatures are inaccurate to identify Fever in emergency department adults.

Authors:  Barbara J Barnett; Stacy Nunberg; Julia Tai; Martin L Lesser; Vladmir Fridman; Patricia Nichols; Richard Powell; Robert Silverman
Journal:  West J Emerg Med       Date:  2011-11

7.  Comparison of two fluid warming devices for maintaining body core temperature during living donor liver transplantation: Level 1 H-1000 vs. Fluid Management System 2000.

Authors:  Sangbin Han; Junghee Choi; Justin Sangwook Ko; Misook Gwak; Suk-Koo Lee; Gaab-Soo Kim
Journal:  Korean J Anesthesiol       Date:  2014-10-27

8.  Risk factors and outcomes for prolonged versus brief fever: a prospective cohort study.

Authors:  Philippe Seguin; Antoine Roquilly; Olivier Mimoz; Pascale Le Maguet; Karim Asehnoune; Sébastien Biederman; Elsa Carise; Yannick Malledant
Journal:  Crit Care       Date:  2012-08-13       Impact factor: 9.097

9.  Comparison of cooling methods to induce and maintain normo- and hypothermia in intensive care unit patients: a prospective intervention study.

Authors:  Cornelia W Hoedemaekers; Mustapha Ezzahti; Aico Gerritsen; Johannes G van der Hoeven
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

Review 10.  A recommended early goal-directed management guideline for the prevention of hypothermia-related transfusion, morbidity, and mortality in severely injured trauma patients.

Authors:  Ryan Perlman; Jeannie Callum; Claude Laflamme; Homer Tien; Barto Nascimento; Andrew Beckett; Asim Alam
Journal:  Crit Care       Date:  2016-04-20       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.