Literature DB >> 10546530

An integrated decoupler for capillary electrophoresis with electrochemical detection: application to analysis of brain microdialysate.

J Qian1, Y Wu, H Yang, A C Michael.   

Abstract

An approach to capillary electrophoresis with electrochemical detection (CE-EC) suitable for determination of dopamine in 1-min brain microdialysate samples is described. The CE-EC system includes an electrochemical detection cell that permits easy, precise, and permanent alignment of a carbon fiber microelectrode with a separation capillary (30-micron i.d., 75-cm length). Amperometric detection was performed at a constant applied potential of 600 mV with respect to a Ag/AgCl reference electrode. Decoupling of the electrophoretic current from the amperometric detector was accomplished with an integrated end-column decoupler prepared by etching the capillary outlet with HF. The decoupler produces baseline noise of 50 fA, or less, in the presence of 10-20-muA current in the separation capillary. The low baseline noise affords low mass (attomoles) and low concentration (nanomolar) detection limits for dopamine and 4-methylcatechol. A peak attributable to dopamine was identified in electropherograms of brain microdialysate samples obtained from anesthetized rats. Identification of the dopamine peak was confirmed by pharmacological methods. Dopamine was readily detected in 1-min brain microdialysate samples. The dopamine concentration in 1-min brain microdialysis samples was significantly altered by drug treatments and by brief electrical stimulation of dopaminergic axons.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10546530     DOI: 10.1021/ac990338f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Characterization of etched electrochemical detection for electrophoresis in micron inner diameter capillaries.

Authors:  Paula R Powell; Lori A Woods; Andrew G Ewing
Journal:  J Sep Sci       Date:  2005-12       Impact factor: 3.645

2.  Impact of microdialysis probes on vasculature and dopamine in the rat striatum: a combined fluorescence and voltammetric study.

Authors:  Christina M Mitala; Yuexiang Wang; Laura M Borland; Moon Jung; Stuart Shand; Simon Watkins; Stephen G Weber; Adrian C Michael
Journal:  J Neurosci Methods       Date:  2008-07-15       Impact factor: 2.390

3.  Cellulose acetate decoupler for on-column electrochemical detection in capillary electrophoresis.

Authors:  D M Osboum; C E Lunte
Journal:  Anal Chem       Date:  2001-12-15       Impact factor: 6.986

4.  Microdialysis probes alter presynaptic regulation of dopamine terminals in rat striatum.

Authors:  Yuexiang Wang; Adrian C Michael
Journal:  J Neurosci Methods       Date:  2012-04-21       Impact factor: 2.390

5.  A parallel dual-electrode detector for capillary electrophoresis.

Authors:  Megan K Dorris; Eric W Crick; Craig E Lunte
Journal:  Electrophoresis       Date:  2012-09       Impact factor: 3.535

6.  Comparison of the brain penetration injury associated with microdialysis and voltammetry.

Authors:  Andrea Jaquins-Gerstl; Adrian C Michael
Journal:  J Neurosci Methods       Date:  2009-06-25       Impact factor: 2.390

7.  Integration of microdialysis sampling and microchip electrophoresis with electrochemical detection.

Authors:  Laura C Mecker; R Scott Martin
Journal:  Anal Chem       Date:  2008-12-01       Impact factor: 6.986

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.