Literature DB >> 10543553

Beating heart surgery: why expect less central nervous system morbidity?

J M Murkin1, W D Boyd, S Ganapathy, S J Adams, R C Peterson.   

Abstract

BACKGROUND: The incidence and etiology of brain dysfunction after conventional coronary artery bypass surgery using cardiopulmonary bypass (CPB) are reviewed.
METHODS: Stroke rates and incidences of cognitive dysfunction from various studies are considered. Mechanisms of injury including cerebral embolization as detected by transcranial Doppler and retinal angiography, and imaging-based evidence for postoperative cerebral edema, are discussed. Preliminary results from a prospective clinical trial assessing cognitive dysfunction after beating heart versus conventional coronary artery bypass with CPB are discussed.
RESULTS: Initial evidence for lower overall postoperative morbidity, and for a lower incidence of cognitive dysfunction specifically, after nonpump coronary revascularization is presented.
CONCLUSIONS: Beating heart surgery results in less potential for generation of cerebral emboli and appears to produce a lower incidence of cognitive dysfunction in both short- and intermediate-term postoperative follow-up periods as compared with conventional coronary artery bypass surgery using CPB.

Entities:  

Mesh:

Year:  1999        PMID: 10543553     DOI: 10.1016/s0003-4975(99)00953-4

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  15 in total

1.  Real-time 4D ultrasound mosaicing and visualization.

Authors:  Laura J Brattain; Robert D Howe
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

2.  GPU based real-time instrument tracking with three-dimensional ultrasound.

Authors:  Paul M Novotny; Jeff A Stoll; Nikolay V Vasilyev; Pedro J del Nido; Pierre E Dupont; Todd E Zickler; Robert D Howe
Journal:  Med Image Anal       Date:  2007-07-05       Impact factor: 8.545

3.  3D ultrasound-guided motion compensation system for beating heart mitral valve repair.

Authors:  Shelten G Yuen; Samuel B Kesner; Nikolay V Vasilyev; Pedro J Del Nido; Robert D Howe
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

4.  A Deployable Transseptal Brace for Stabilizing Cardiac Catheters.

Authors:  Leah P Gaffney; Paul M Loschak; Robert D Howe
Journal:  J Mech Des N Y       Date:  2018-05-11       Impact factor: 3.251

5.  Robotic Motion Compensation for Beating Heart Intracardiac Surgery.

Authors:  Shelten G Yuen; Daniel T Kettler; Paul M Novotny; Richard D Plowes; Robert D Howe
Journal:  Int J Rob Res       Date:  2009-10-01       Impact factor: 4.703

6.  Robotic Force Stabilization for Beating Heart Intracardiac Surgery.

Authors:  Shelten G Yuen; Michael C Yip; Nikolay V Vasilyev; Douglas P Perrin; Pedro J Del Nido; Robert D Howe
Journal:  Med Image Comput Comput Assist Interv       Date:  2009-10-01

7.  Cognitive dysfunction following cardiovascular surgery.

Authors:  Manabu Sakurai; Yoshiharu Takahara; Shigeyasu Takeuchi; Kenji Mogi
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-05

8.  Passive markers for tracking surgical instruments in real-time 3-D ultrasound imaging.

Authors:  Jeffrey Stoll; Hongliang Ren; Pierre E Dupont
Journal:  IEEE Trans Med Imaging       Date:  2011-10-25       Impact factor: 10.048

9.  Force Tracking with Feed-Forward Motion Estimation for Beating Heart Surgery.

Authors:  Shelten G Yuen; Douglas P Perrin; Nikolay V Vasilyev; Pedro J Del Nido; Robert D Howe
Journal:  IEEE Trans Robot       Date:  2010-08-16       Impact factor: 5.567

10.  Predictors of prolonged ICU stay after on-pump versus off-pump coronary artery bypass grafting.

Authors:  Jan Bucerius; Jan F Gummert; Thomas Walther; Nicolas Doll; Volkmar Falk; Dierk V Schmitt; Friedrich W Mohr
Journal:  Intensive Care Med       Date:  2003-09-20       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.