Skin absorption in vitro of glycol ethers.

F Larese Filon1, A Fiorito, G Adami, P Barbieri, N Coceani, R Bussani, E Reisenhofer.   

Abstract

OBJECTIVES: The increased use of glycol ethers (GEs) for water-based paints and cleaning products, combined with a lack of information about many of these products, particularly with regard to the effects of percutaneous exposure, led us to evaluate the skin absorption rates of a group of glycol ethers in vitro.
METHODS: Skin permeation was calculated using the Franz cell method with human skin. A physiological solution was used as the receiving phase. The amount of solvent passing through the skin was analysed with a gas chromatographic technique employing flame ionization detection. A permeation profile was obtained and steady state, lag time and permeation constant flux was calculated for each of the following solvents: ethylene glycol monoethyl ether (EGMEE), propylene glycol mono-methyl ether (PGMME); propylene glycol mono-methyl ether acetate (PGMMEac); 2-propylene glycol 1-butyl ether (2PG1BE), ethylene glycol dimethyl ether (EGDME), ethylene glycol diethyl ether (EGDEE) and diethylene glycol dimethyl ether (DEGDME). All solvents were tested in their pure form and with 70% acetone.
RESULTS: For all solvents tested the lag time was less than 2 h, and for the majority of them was about 60 min. Flux at steady state ranged between 0.017 +/- 0.005 and 3.435 +/- 1.897 mg/cm(2)/h and permeation rate was from 0.0192 to 1.02 x 10(-3) cm/h. The presence of acetone in the solution caused a reduction in lag time and an increase in permeation rate, higher for EGMEE, lower for EGDEE, indicating the enhancing effect of this mixture of solvents.
CONCLUSIONS: Our results confirm the high percutaneous absorption of the GEs tested. The Franz method might be helpful for obtaining a grading of skin notation for hydrophilic substances: in the case of glycol ethers, it can give us precise information about permeation risk, particularly important in the evaluation of exposure. In the case of solvents with high dermal absorption, the air concentration is no longer a sufficient measure of the total exposure to workers, and therefore merely respecting threshold limit values (TLVs) in the air is not necessarily enough to protect them.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10541914     DOI: 10.1007/s004200050402

Source DB:  PubMed          Journal:  Int Arch Occup Environ Health        ISSN: 0340-0131            Impact factor:   3.015


  4 in total

1.  In vitro evaluation of the efficacy of skin barrier creams and protective gloves on percutaneous absorption of industrial solvents.

Authors:  G Korinth; S Geh; K H Schaller; H Drexler
Journal:  Int Arch Occup Environ Health       Date:  2003-05-09       Impact factor: 3.015

2.  In vitro percutaneous absorption of cobalt.

Authors:  Francesca Larese Filon; Giovanni Maina; Gianpiero Adami; Marta Venier; Nicoletta Coceani; Rossana Bussani; Marilena Massiccio; Pierluigi Barbieri; Paolo Spinelli
Journal:  Int Arch Occup Environ Health       Date:  2003-06-19       Impact factor: 3.015

3.  Quantification of N-phenyl-2-naphthylamine by gas chromatography and isotope-dilution mass spectrometry and its percutaneous absorption ex vivo under workplace conditions.

Authors:  Eike Maximilian Marek; Stephan Koslitz; Tobias Weiss; Manigé Fartasch; Gerhard Schlüter; Heiko Udo Käfferlein; Thomas Brüning
Journal:  Arch Toxicol       Date:  2017-09-12       Impact factor: 5.153

4.  Percutaneous absorption of thirty-eight organic solvents in vitro using pig skin.

Authors:  Linda Schenk; Matias Rauma; Martin N Fransson; Gunnar Johanson
Journal:  PLoS One       Date:  2018-10-31       Impact factor: 3.240

  4 in total