Literature DB >> 10540141

A 14-year experience with 6 cm as a criterion for surgical treatment of abdominal aortic aneurysm.

R A Scott1, H A Ashton, M J Lamparelli, G J Harris, J W Stevens.   

Abstract

BACKGROUND: It remains unclear when to recommend operation for an asymptomatic abdominal aortic aneurysm (AAA). This study examined a prospective series of patients for whom standard criteria were applied.
METHODS: Some 584 consecutive patients with an AAA of diameter 3 cm or greater detected by ultrasonographic screening have been observed for up to 14 years. Repeat ultrasonographic examinations have been performed at intervals. Surgery was not considered unless the aneurysm measured 6 cm in diameter, expanded at a rate equivalent to at least 1 cm per year, caused the patient symptoms, or an iliac aneurysm was present that required treatment.
RESULTS: Operation was performed on 127 patients; the majority (80; 63 per cent) had an aneurysm that reached 6 cm in diameter. Use of the above criteria prevented rupture in all but 24 (4 per cent) of the 584 patients over the 14-year interval. Of these 24 patients, 11 were unfit for planned surgery and eight declined operation or follow-up. Rupture in the five remaining patients (1 per cent) who were available for treatment compared favourably with the reported 30-day mortality rate for elective surgical treatment of 1.4-12 per cent.
CONCLUSION: Repeated observation is preferable to surgical intervention until an aortic aneurysm measures 6 cm in diameter, expands by 1 cm per annum or causes symptoms. Presented as a poster to the 52nd Annual Meeting of the Society for Vascular Surgery, San Diego, California, USA, June 1998

Entities:  

Mesh:

Year:  1999        PMID: 10540141     DOI: 10.1046/j.1365-2168.1999.01227.x

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  5 in total

1.  Fitness to drive: a survey of the knowledge and practice of vascular surgeons regarding patients with carotid disease and aortic aneurysms.

Authors:  W B Campbell; M Schuijtvlot; K L Allington; J J Earnshaw
Journal:  Ann R Coll Surg Engl       Date:  2002-03       Impact factor: 1.891

2.  Fluid-structure interaction modeling of abdominal aortic aneurysms: the impact of patient-specific inflow conditions and fluid/solid coupling.

Authors:  Santanu Chandra; Samarth S Raut; Anirban Jana; Robert W Biederman; Mark Doyle; Satish C Muluk; Ender A Finol
Journal:  J Biomech Eng       Date:  2013-08       Impact factor: 2.097

Review 3.  [Simulation of blood flow within the abdominal aorta. Computational fluid dynamics in abdominal aortic aneurysms before and after interventions].

Authors:  T Frauenfelder; E Boutsianis; H Alkadhi; B Marincek; T Schertler
Journal:  Radiologe       Date:  2007-11       Impact factor: 0.635

4.  Towards patient-specific risk assessment of abdominal aortic aneurysm.

Authors:  M Breeuwer; S de Putter; U Kose; L Speelman; K Visser; F Gerritsen; R Hoogeveen; R Krams; H van den Bosch; J Buth; T Gunther; B Wolters; E van Dam; F van de Vosse
Journal:  Med Biol Eng Comput       Date:  2008-09-23       Impact factor: 2.602

5.  Fluid-structure interaction in abdominal aortic aneurysms: effects of asymmetry and wall thickness.

Authors:  Christine M Scotti; Alexander D Shkolnik; Satish C Muluk; Ender A Finol
Journal:  Biomed Eng Online       Date:  2005-11-04       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.