Literature DB >> 10539706

The conventional ultrasonic nebulizer proved inefficient in nebulizing a suspension.

K Nikander1, M Turpeinen, P Wollmer.   

Abstract

A study was undertaken to compare the amount of nebulized budesonide suspension and nebulized terbutaline sulphate solution inhaled by healthy adult subjects when conventional jet and ultrasonic nebulizers were used. Ten healthy subjects (5 male; age range, 16-52 years) used two conventional nebulizers: the Spira Elektro 4 jet nebulizer (Respiratory Care Center, Hämeenlinna, Finland) and the Spira Ultra ultrasonic nebulizer (Respiratory Care Center) in a breath-synchronized mode with each drug. The amount of drug inhaled, the inhaled mass, was defined as the amount of drug deposited on a filter between the inspiratory port of the nebulizer and the mouthpiece. The amount of budesonide and terbutaline sulphate was determined by reversed-phase high-performance liquid chromatography. Single-dose respules were used (0.5 mg of budesonide and 5.0 mg of terbutaline sulphate), and nebulization time up to the defined gravimetric output was recorded. The inhaled mass of budesonide varied depending on the nebulizer used, whereas the inhaled mass of terbutaline was unaffected by the choice of nebulizer. The median inhaled mass of budesonide was 31.4% of the nominal dose (i.e., dose of drug in the respule per label claim) with the Spira Elektro 4 and 9.9% with the Spira Ultra, whereas the median inhaled mass of terbutaline was 50% with the Spira Elektro 4 and 52% with the Spira Ultra. It appears that a suspension is generally more difficult to nebulize than a solution and that the budesonide suspension should not be used in conventional ultrasonic nebulizers.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10539706     DOI: 10.1089/jam.1999.12.47

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  8 in total

1.  Faraday instability-based micro droplet ejection for inhalation drug delivery.

Authors:  C S Tsai; R W Mao; S K Lin; Y Zhu; S C Tsai
Journal:  Technology (Singap World Sci)       Date:  2014-03

2.  Evaluation of patient-reported outcomes and quality of life with the I-neb AAD system in patients with chronic obstructive pulmonary disease.

Authors:  Nicola Goodman; Mike Morgan; Kurt Nikander; Sarah Hinch; Steven Coughlin
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2010-04       Impact factor: 2.849

3.  Evaluation of a nanoemulsion-based formulation for respiratory delivery of budesonide by nebulizers.

Authors:  Amir Amani; Peter York; Henry Chrystyn; Brian J Clark
Journal:  AAPS PharmSciTech       Date:  2010-07-24       Impact factor: 3.246

Review 4.  Once-daily inhaled corticosteroids in children with asthma: nebulisation.

Authors:  G Shapiro
Journal:  Drugs       Date:  1999       Impact factor: 9.546

Review 5.  Budesonide inhalation suspension for the treatment of asthma in infants and children.

Authors:  William E Berger
Journal:  Drugs       Date:  2005       Impact factor: 9.546

Review 6.  Budesonide inhalation suspension: a review of its use in infants, children and adults with inflammatory respiratory disorders.

Authors:  K M Hvizdos; B Jarvis
Journal:  Drugs       Date:  2000-11       Impact factor: 9.546

Review 7.  Use of inhaler devices in pediatric asthma.

Authors:  Fernando Maria De Benedictis; David Selvaggio
Journal:  Paediatr Drugs       Date:  2003       Impact factor: 3.022

8.  Investigation of Factors Affecting Aerodynamic Performance of Nebulized Nanoemulsion.

Authors:  Hosein Kamali; Shayan Abbasi; Mohammad Ali Amini; Amir Amani
Journal:  Iran J Pharm Res       Date:  2016       Impact factor: 1.696

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.