The diagnostic significance of the multifocal pattern visual evoked potential in glaucoma.

S L Graham1, A Klistorner.   

Abstract

The concept of objective perimetry is an exciting one because it strives to assess glaucoma damage without relying on psychophysical testing. The recent introduction of multifocal stimulus recording has enhanced our ability to examine the human visual field using electrophysiology. A multifocal pattern visual evoked potential can now be recorded, testing up to 60 sites within the central 25 degrees. The test requires only that the subject fixate on a target, while a cortically scaled dartboard pattern stimulus undergoes pseudorandom alternation within each of the test segments. In its present configuration the test requires at least 8 minutes recording time per eye. Modified bipolar electrode positions are required to ensure that adequate signals are detected from all parts of the visual field. In glaucoma patients, pattern visual evoked potential amplitudes have been shown to reflect visual field loss with reduction of signal amplitude in the affected areas. This technique represents the first major step toward objective detection of visual field defects in glaucoma.

Entities:  

Mesh:

Year:  1999        PMID: 10537765     DOI: 10.1097/00055735-199904000-00011

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  5 in total

1.  Correlation between full-field and multifocal VEPs in optic neuritis.

Authors:  Alexander Klistorner; Clare Fraser; Raymond Garrick; Stuart Graham; Hemamalini Arvind
Journal:  Doc Ophthalmol       Date:  2007-08-07       Impact factor: 2.379

2.  Multifocal pattern electroretinogram does not demonstrate localised field defects in glaucoma.

Authors:  A I Klistorner; S L Graham; A Martins
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

3.  Multifocal VEP and OCT in optic neuritis: a topographical study of the structure-function relationship.

Authors:  Alexander Klistorner; H Arvind; T Nguyen; R Garrick; M Paine; S Graham; J O'Day; C Yiannikas
Journal:  Doc Ophthalmol       Date:  2008-09-09       Impact factor: 2.379

4.  In vivo functional imaging of intrinsic scattering changes in the human retina with high-speed ultrahigh resolution OCT.

Authors:  V J Srinivasan; Y Chen; J S Duker; J G Fujimoto
Journal:  Opt Express       Date:  2009-03-02       Impact factor: 3.894

5.  Comparison of the reliability of multifocal visual evoked cortical potentials generated by pattern reversal and pattern pulse stimulation.

Authors:  G S Souza; H B Schakelford; A L A Moura; B D Gomes; D F Ventura; M E C Fitzgerald; L C L Silveira
Journal:  Braz J Med Biol Res       Date:  2012-07-12       Impact factor: 2.590

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.