Failure of a metal-on-metal total hip arthroplasty from progressive osteolysis.

C Klapperich1, J Graham, L Pruitt, M D Ries.   

Abstract

Ultra-high-molecular weight polyethylene (UHMWPE) wear, debris-induced osteolysis is a frequent cause of failure of total hip arthroplasty. Metal-on-metal total hip arthroplasty eliminates the generation of UHMWPE particulate debris. Although the volumetric wear of a metal-on-metal articulation may be lower than a metal-UHMWPE articulation, the number of particles may be higher. Osteolysis can develop in response to metallic and UHMWPE debris. The following case of massive osteolysis associated with large amounts of cobalt-chrome wear debris shows adhesive and abrasive wear mechanisms, as well as wear caused by third-body cobalt-chrome debris and impingement of the femoral component against the rim of the acetabular cup, which led to failure of a metal-on-metal total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10537267     DOI: 10.1016/s0883-5403(99)90042-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Revisions of monoblock metal-on-metal THAs have high early complication rates.

Authors:  Louis S Stryker; Susan M Odum; Thomas K Fehring; Bryan D Springer
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

2.  In vitro biological and tribological properties of transparent magnesium aluminate (Spinel) and aluminum oxynitride (ALON®).

Authors:  Subhadip Bodhak; Vamsi Krishna Balla; Susmita Bose; Amit Bandyopadhyay; Uday Kashalikar; Santosh K Jha; Suri Sastri
Journal:  J Mater Sci Mater Med       Date:  2011-05-12       Impact factor: 3.896

3.  Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.

Authors:  Ian Holloway; William L Walter; Bernie Zicat; William K Walter
Journal:  Int Orthop       Date:  2008-11-05       Impact factor: 3.075

Review 4.  [Biomechanical aspects of the implant fixation and kinematics of hip resurfacing systems].

Authors:  R Bader; D Klüss; L Gerdesmeyer; E Steinhauser
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

5.  On interlayer stability and high-cycle simulator performance of diamond-like carbon layers for articulating joint replacements.

Authors:  Kerstin Thorwarth; Götz Thorwarth; Renato Figi; Bernhard Weisse; Michael Stiefel; Roland Hauert
Journal:  Int J Mol Sci       Date:  2014-06-11       Impact factor: 5.923

6.  Modification of the Ceramic Implant Surfaces from Zirconia by the Magnetron Sputtering of Different Calcium Phosphate Targets: A Comparative Study.

Authors:  Anna I Kozelskaya; Evgeny N Bolbasov; Alexey S Golovkin; Alexander I Mishanin; Alice N Viknianshchuk; Evgeny V Shesterikov; Аndrey Ashrafov; Vadim A Novikov; Alexander Y Fedotkin; Igor A Khlusov; Sergey I Tverdokhlebov
Journal:  Materials (Basel)       Date:  2018-10-11       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.