Literature DB >> 10532561

The influence of hydroxyapatite granules on the healing of a segmental defect filled with autologous bone marrow.

B Wippermann1, C Donow, H E Schratt, F C den Boer, T Blokhuis, P Patka.   

Abstract

Hydroxyapatite(HA) ceramics are frequently used as a bone graft substitutes for the filling of bony defects. The addition of autologous bone marrow to HA ceramics does improve defect healing. There is conflicting evidence in the literature whether autologous bone marrow transplantation alone is as effective as the combination of HA ceramics and bone marrow combined. It was the purpose of this study to identify the role of additional HA ceramic granules on the healing of a sheep tibia segmental defect filled with autologous bone marrow. After permission of the local animal rights committee was obtained, a 3 cm segmental defect in the midshaft of 31 adult sheep was stabilized with an unreamed tibia nail. The animals were divided into 4 groups according to the mode of defect filling: HA plus autologous bone marrow (HA + MAR) (n = 8), autologous bone marrow (MAR) (n = 9), empty defect (DEF) (n = 6), cancellous bone graft (CAN) (n = 8). After three months follow up animals were sacrificed and analysed for the key parameters of union and maximum torque at failure. One nonunion was present in each of the HA + MAR, MAR, and CAN groups. Four of the six animals in the DEF group developed a nonunion. Maximum torque at failure was reported as percentage of the intact contralateral tibia: HA + MAR 39% +/- 24%, MAR 26% +/- 17%, DEF 22% +/- 13%, CAN 41% +/- 20%. The difference between the groups was statistically significant, but appeared to be relevant. We conclude from our data, that HA ceramics do improve healing of a segmental defect in the sheep tibia filled with autologous bone marrow. The results of this combination are comparable to cancellous autograft.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10532561

Source DB:  PubMed          Journal:  Ann Chir Gynaecol        ISSN: 0355-9521


  2 in total

1.  Double-plating of ovine critical sized defects of the tibia: a low morbidity model enabling continuous in vivo monitoring of bone healing.

Authors:  Joachim A Hahn; Tanja S Witte; Daniel Arens; Alexandra Pearce; Simon Pearce
Journal:  BMC Musculoskelet Disord       Date:  2011-09-29       Impact factor: 2.362

2.  [Internal fixation of meta- and diaphyseal intercalary bone defects after tumour resection with intramedullary nailing and porous polymethylmetacrylate (PMMA) spacer].

Authors:  A Biewener; J Meyer; C Rentsch; R Grass; K P Günther; H Zwipp; S Rammelt
Journal:  Orthopade       Date:  2007-02       Impact factor: 1.087

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.