Right pneumothorax resulting from an endocardial screw-in atrial lead.

W J Ho1, C T Kuo, K H Lin.   

Abstract

Right pneumothorax complicated by an endocardial atrial lead has never been reported. Herein, we report on a small-build 79-year-old Taiwanese woman who suffered from complete AV block and underwent dual-chamber permanent pacemaker implantation. An active fixation screw-in atrial lead was chosen. The procedure was complicated by right pneumothorax associated with atrial perforation. Since simple measurements of the implantation parameters could not be used to predict the occurrence of perforation, great caution should be taken in to avoid overscrewing the atrial lead, and in scrutinizing the penetration depth of the helix of the lead under fluoroscopy.

Entities:  

Mesh:

Year:  1999        PMID: 10531188     DOI: 10.1378/chest.116.4.1133

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  9 in total

1.  Pneumomediastinum and right sided pneumothorax following dual chamber-ICD implantation.

Authors:  Jonathan Rosman; Michael D Shapiro; Sam Hanon
Journal:  J Interv Card Electrophysiol       Date:  2007-02-24       Impact factor: 1.900

2.  Pacemaker insertion.

Authors:  Maria Kotsakou; Ioannis Kioumis; George Lazaridis; Georgia Pitsiou; Sofia Lampaki; Antonis Papaiwannou; Anastasia Karavergou; Kosmas Tsakiridis; Nikolaos Katsikogiannis; Ilias Karapantzos; Chrysanthi Karapantzou; Sofia Baka; Ioannis Mpoukovinas; Vasilis Karavasilis; Aggeliki Rapti; Georgia Trakada; Athanasios Zissimopoulos; Konstantinos Zarogoulidis; Paul Zarogoulidis
Journal:  Ann Transl Med       Date:  2015-03

3.  Right coronary artery perforation by an active-fixation atrial pacing lead resulting in life-threatening tamponade.

Authors:  Eiichiro Nakagawa; Yukio Abe; Ryushi Komatsu; Takahiko Naruko; Akira Itoh
Journal:  J Arrhythm       Date:  2015-03-16

4.  Contralateral Pneumothorax in Left Sided CRT Device Implantation.

Authors:  Syamkumar M Divakara Menon; Glen L Sumner; Carlos S Ribas; Jeff S Healey; Girish M Nair; Stuart J Connolly; Carlos A Morillo
Journal:  Indian Pacing Electrophysiol J       Date:  2011-02-08

5.  Where does it lead? Imaging features of cardiovascular implantable electronic devices on chest radiograph and CT.

Authors:  Rotem S Lanzman; Joachim Winter; Dirk Blondin; Günter Fürst; Axel Scherer; Falk R Miese; Suhny Abbara; Patric Kröpil
Journal:  Korean J Radiol       Date:  2011-08-24       Impact factor: 3.500

6.  A Shocking Case of Pacemaker Lead Perforation.

Authors:  Eli Simsolo; Bruce L Wilkoff
Journal:  JACC Case Rep       Date:  2022-09-21

7.  Loss of capture late after right ventricular pacing lead revision: what is the mechanism?

Authors:  Joachim Seegers; Lars Lüthje; Markus Zabel; Dirk Vollmann
Journal:  Clin Res Cardiol       Date:  2009-06-25       Impact factor: 5.460

8.  Diaphragmatic stimulation: a case of atrial lead dislodgement and right atrium perforation.

Authors:  Mh Namazi; R Karbasi-Afshar; M Safi; Ar Serati
Journal:  Indian Pacing Electrophysiol J       Date:  2008-04-01

9.  Contralateral Pneumothorax after the Implantation of a Dual Chamber Pacemaker.

Authors:  Cyrus M Munguti; John M Eliveha; Freidy A Eid
Journal:  Kans J Med       Date:  2017-08-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.