Literature DB >> 10529928

Evaluation of a portable fundus camera for use in the teleophthalmologic diagnosis of glaucoma.

K Yogesan1, I J Constable, C J Barry, R H Eikelboom, W Morgan, M L Tay-Kearney, L Jitskaia.   

Abstract

PURPOSE: The digital images of the optic disk from a portable fundus camera were evaluated for suitability in teleophthalmologic screening for glaucoma.
METHODS: Fifty-one eyes of 27 consecutive patients from our glaucoma clinic were dilated and photographed with a Zeiss FF retinal camera (Carl Zeiss, Oberkochen, Germany) and a portable Nidek NM-100 (Nidek, Tokyo, Japan) fundus camera. Digital images from the portable fundus camera were digitized, compressed and stored in a Fujix DF-10M (Fuji, Tokyo, Japan) digitizer. Lossy compressed digital images and photographs from the Zeiss camera were presented separately in random order to three ophthalmologists for estimation of vertical cup:disk ratios (VCDR) and to evaluate image quality as good, acceptable, or unacceptable for screening glaucoma. Gold standard VCDRs were measured from monoscopic photographic slides obtained using the Zeiss camera by a fourth ophthalmologist.
RESULTS: Measurement of agreement (Kappa values) between estimated VCDR of digital images and photographs by the three ophthalmologists were 0.52, 0.38, and 0.50 respectively. Agreement between gold standard and estimated VCDR from photographs were 0.87, 0.45, and 0.84 respectively (specificity between 79% and 97%, sensitivity between 70% and 95%). Kappa values obtained between gold standard and estimated VCDR from digital images were 0.52, 0.49, and 0.49, respectively (specificity between 68% and 79%, sensitivity between 67% and 87%.
CONCLUSION: Moderate to good agreement indicates that the digital images from the portable fundus camera may be suitable for optic disk assessment in the current configuration. This easy to use Nidek hand-held camera could be a viable instrument for teleophthalmology if a better digitizing system is incorporated to improve the quality of the images.

Entities:  

Mesh:

Year:  1999        PMID: 10529928

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  14 in total

1.  Validating retinal fundus image analysis algorithms: issues and a proposal.

Authors:  Emanuele Trucco; Alfredo Ruggeri; Thomas Karnowski; Luca Giancardo; Edward Chaum; Jean Pierre Hubschman; Bashir Al-Diri; Carol Y Cheung; Damon Wong; Michael Abràmoff; Gilbert Lim; Dinesh Kumar; Philippe Burlina; Neil M Bressler; Herbert F Jelinek; Fabrice Meriaudeau; Gwénolé Quellec; Tom Macgillivray; Bal Dhillon
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-01       Impact factor: 4.799

2.  Glaucoma Screening in Nepal: Cup-to-Disc Estimate With Standard Mydriatic Fundus Camera Compared to Portable Nonmydriatic Camera.

Authors:  Sarah E Miller; Suman Thapa; Alan L Robin; Leslie M Niziol; Pradeep Y Ramulu; Maria A Woodward; Indira Paudyal; Ian Pitha; Tyson N Kim; Paula Anne Newman-Casey
Journal:  Am J Ophthalmol       Date:  2017-07-19       Impact factor: 5.258

3.  Glaucoma Patient Knowledge, Perceptions, and Predispositions for Telemedicine.

Authors:  Lindsay A Rhodes; Carrie E Huisingh; Gerald McGwin; Christopher A Girkin; Cynthia Owsley
Journal:  J Glaucoma       Date:  2019-06       Impact factor: 2.503

4.  Screening for Diabetic Retinopathy Using a Portable, Noncontact, Nonmydriatic Handheld Retinal Camera.

Authors:  Wenlan Zhang; Peter Nicholas; Stefanie Gail Schuman; Michael John Allingham; Ambar Faridi; Tushar Suthar; Scott William Cousins; Sasapin Grace Prakalapakorn
Journal:  J Diabetes Sci Technol       Date:  2016-07-11

5.  [Ophthalmic disease in diabetes mellitus: management from primary health care].

Authors:  María José Sender Palacios; María Vernet Vernet; Miguel Maseras Bové; Antoni Salvador Playà; Laia Pascual Batlle; Juan Carlos Ondategui Parra; Esther Jovell Fernández
Journal:  Aten Primaria       Date:  2010-04-07       Impact factor: 1.137

6.  Gaps in Glaucoma care: A systematic review of monoscopic disc photos to screen for glaucoma.

Authors:  Paula Anne Newman-Casey; Angela J Verkade; Gale Oren; Alan L Robin
Journal:  Expert Rev Ophthalmol       Date:  2014-12

7.  Nonmydriatic fundus photography for teleophthalmology diabetic retinopathy screening in rural and urban clinics.

Authors:  Eric K Chin; Bruna V Ventura; Kai-Yin See; Joann Seibles; Susanna S Park
Journal:  Telemed J E Health       Date:  2013-11-12       Impact factor: 3.536

8.  A Deep Learning Algorithm to Quantify Neuroretinal Rim Loss From Optic Disc Photographs.

Authors:  Atalie C Thompson; Alessandro A Jammal; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2019-01-26       Impact factor: 5.258

9.  Clinical Application of a Smartphone-Based Ophthalmic Camera adapter in Under-Resourced Settings in Nepal.

Authors:  Carmel Mercado; John Welling; Matthew Oliva; Jack Li; Reeta Gurung; Sanduk Ruit; Geoff Tabin; David Chang; Suman Thapa; David Myung
Journal:  J Mob Technol Med       Date:  2017-12-28

Review 10.  The Future Is Now: Incorporating Telemedicine into Glaucoma Care.

Authors:  Monica K Ertel; Malik Y Kahook; Cara E Capitena Young
Journal:  Curr Ophthalmol Rep       Date:  2021-07-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.