Literature DB >> 10528833

Modification and application of a Pelorus Mark III stereotactic system for CT-guided brain biopsy in 50 dogs.

P D Koblik1, R A LeCouteur, R J Higgins, J Fick, G D Kortz, B K Sturges, P J Pascoe.   

Abstract

The Pelorus Mark III Stereotactic System is a commercially available device for CT-guided stereotactic brain biopsy in people. With relatively minor modifications, this device was used to safely and accurately perform CT-guided stereotactic brain biopsies in 50 dogs with intracranial lesions. Modifications were necessary to accommodate a 90 degree shift in orientation of the canine head compared to the human head during the imaging phase of the procedure, and to facilitate other phases of the biopsy procedure that are affected by the uneven and variable topography of the canine skull. Description of a typical CT-guided brain biopsy procedure in dogs using the modified Pelorus Mark III Stereotactic System is provided. Accuracy of biopsy needle placement was determined by comparing the x, y and z coordinates of the biopsy target site with the actual coordinates of the needle tip on CT images. Mean needle placement error was 3.5 +/- 1.6 mm. Needle placement error was not significantly related to operator experience, dog size (body weight), or needle path length, however, needle placement error was significantly affected by lesion location.

Entities:  

Mesh:

Year:  1999        PMID: 10528833     DOI: 10.1111/j.1740-8261.1999.tb00370.x

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  11 in total

1.  Use of a disposable real-time CT stereotactic navigator device for minimally invasive dog brain biopsy through a mini-burr hole.

Authors:  Thomas Flegel; Michael Podell; Philip A March; Donald W Chakeres
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

2.  A Simple and Inexpensive Stereotactic Guidance Frame for MRI-Guided Brain Biopsy in Canines.

Authors:  Alexander D Squires; Yabiao Gao; Sean F Taylor; Marc Kent; Zion Tsz Ho Tse
Journal:  J Med Eng       Date:  2014-05-18

3.  Accurate external localization of the left frontal cortex in dogs by using pointer based frameless neuronavigation.

Authors:  Robrecht Dockx; Kathelijne Peremans; Romain Duprat; Lise Vlerick; Nick Van Laeken; Jimmy H Saunders; Ingeborgh Polis; Filip De Vos; Chris Baeken
Journal:  PeerJ       Date:  2017-07-10       Impact factor: 2.984

4.  Feasability of a Frameless Brain Biopsy System for Companion Animals Using Cone-Beam CT-Based Automated Registration.

Authors:  Felix Meneses; Arianna Maiolini; Franck Forterre; Anna Oevermann; Daniela Schweizer-Gorgas
Journal:  Front Vet Sci       Date:  2022-02-09

5.  Validation of a magnetic resonance imaging guided stereotactic access to the ovine brainstem.

Authors:  Anne Staudacher; Anna Oevermann; Michael H Stoffel; Daniela Gorgas
Journal:  BMC Vet Res       Date:  2014-09-22       Impact factor: 2.741

Review 6.  Advances in diagnostic and treatment modalities for intracranial tumors.

Authors:  P J Dickinson
Journal:  J Vet Intern Med       Date:  2014-05-09       Impact factor: 3.333

7.  Placement of deep brain electrodes in the dog using the Brainsight frameless stereotactic system: a pilot feasibility study.

Authors:  S Long; S Frey; D R Freestone; M LeChevoir; P Stypulkowski; J Giftakis; M Cook
Journal:  J Vet Intern Med       Date:  2013-11-16       Impact factor: 3.333

8.  Frame-Based Stereotactic Biopsy of Canine Brain Masses: Technique and Clinical Results in 26 Cases.

Authors:  John Henry Rossmeisl; Rudy T Andriani; Thomas E Cecere; Kevin Lahmers; Tanya LeRoith; Kurt L Zimmerman; Denise Gibo; Waldemar Debinski
Journal:  Front Vet Sci       Date:  2015-07-27

9.  A pilot study of optical neuronavigation-guided brain biopsy in the horse using anatomic landmarks and fiducial arrays for patient registration.

Authors:  Lawrence Santistevan; Jeremiah Easley; Audrey Ruple; Sam Monck; Elissa Randall; Fred Wininger; Rebecca A Packer
Journal:  J Vet Intern Med       Date:  2020-05-29       Impact factor: 3.333

10.  Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs.

Authors:  Sarah Gutmann; Dirk Winkler; Marcel Müller; Robert Möbius; Jean-Pierre Fischer; Peter Böttcher; Ingmar Kiefer; Ronny Grunert; Thomas Flegel
Journal:  J Vet Intern Med       Date:  2020-02-24       Impact factor: 3.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.