Literature DB >> 10527444

Algorithm for the diagnosis and treatment of endoleaks.

L A Karch1, J P Henretta, K J Hodgson, M A Mattos, D E Ramsey, R B McLafferty, D S Sumner.   

Abstract

BACKGROUND: Endoluminal grafting of abdominal aortic aneurysms (AAA) has shown promising early results. However, endoleaks present a new and challenging obstacle to successful aneurysm exclusion. We report our experience with primary, persistent endoleaks and provide an algorithm for their diagnosis and management.
METHODS: Over a 19-month period, 73 patients underwent endoluminal repair of their AAAs using a modular bifurcated endograft as part of a US FDA Investigational Device Exemption trial. Spiral computed tomography (CT) scanning was performed prior to discharge after repair to evaluate for complete aneurysm exclusion. If no endoleak was present on that initial CT scan, color-flow duplex scanning was performed at 1 month, with repeat CT scanning at 6 months and 1 year. If the initial CT scan revealed the presence of an endoleak, repeat CT scanning was performed at 2 weeks, 1 month, and 3 months, or until the endoleak resolved. Any patient with an endoleak that persisted beyond 3 months underwent angiographic evaluation to localize the source of the leak.
RESULTS: At 1 month, 62 patients (85%) had successful aneurysm exclusion. The remaining 11 patients (15%) had primary endoleaks, 8 (11%) of which persisted beyond 3 months, prompting angiographic evaluation. In 2 patients the endoleak was related to a graft-graft or graft-arterial junction. One was from the endograft terminus in the common iliac artery and was successfully embolized, along with its outflow lumbar artery. The other required placement of an additional endograft component across a leaking graft-graft junction to successfully exclude the aneurysm. The remaining six endoleaks were due to collateral flow through the aneurysm sac. In 4 cases this was lumbar to lumbar flow fed by hypogastric artery collaterals to the inflow lumbar artery. In the remaining 2 patients the endoleak was found to be due to flow between a lumbar and inferior mesenteric artery. Resolution of the endoleak by coil embolization of the feeding hypogastric artery branch in 1 patient was unsuccessful due to rapid recruitment of another hypogastric branch. Two of the six collateral flow endoleaks have resolved spontaneously without treatment, while the remaining cases have been followed up without evidence of aneurysm expansion.
CONCLUSION: Systematic postoperative surveillance facilitates proper diagnosis and treatment of endoleaks. This involves serial CT scans to detect the presence of endoleaks, followed by angiography to determine their etiology and guide treatment, if clinically indicated.

Entities:  

Mesh:

Year:  1999        PMID: 10527444     DOI: 10.1016/s0002-9610(99)00155-5

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  5 in total

Review 1.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

2.  Successful treatment of type I endoleak of common iliac artery with balloon expandable stent (Palmaz XL stent) during endovascular aneurysm repair.

Authors:  Jong Hyuk Ahn; Jang Yong Kim; Yong Sun Jeon; Soon Gu Cho; Jay K Park; Ki Jong Lee; Kee Chun Hong
Journal:  J Korean Surg Soc       Date:  2011-12-27

3.  Strategies of endoleak management following endoluminal treatment of abdominal aortic aneurysms in 95 patients: how, when and why.

Authors:  G Barbiero; A Baratto; F Ferro; J Dall'Acqua; C Fittà; D Miotto
Journal:  Radiol Med       Date:  2008-09-13       Impact factor: 3.469

4.  Laparoscopic transperitoneal clipping of the inferior mesenteric artery for the management of type II endoleak after endovascular repair of an aneurysm.

Authors:  P Ho; W L Law; P H M Tung; J T C Poon; A C W Ting; S W K Cheng
Journal:  Surg Endosc       Date:  2004-05       Impact factor: 4.584

5.  Initial experience with Duplex scan combined with contrast-enhanced ultrasound for follow-up of endovascular abdominal aortic aneurysm repair.

Authors:  Carolina Brito Faustino; Carlos Ventura; Maria Fernanda Cassino Portugal; André Brunheroto; Marcelo Passos Teivelis; Nelson Wolosker
Journal:  J Vasc Bras       Date:  2021-11-01
  5 in total