Literature DB >> 10527094

Strength assessment in postpolio syndrome: validity of a hand-held dynamometer in detecting change.

F Nollet1, A Beelen.   

Abstract

OBJECTIVES: To investigate the validity, the intraexaminer and interexaminer reproducibility, and the ability to detect change of a hand-held dynamometer (HHD) in strength measurements in former polio subjects.
DESIGN: HHD measurement of knee extensor strength was compared with the criterion standard of a chair dynamometer measurement in 49 subjects. The "break" method was used for HHD measurements. Reproducibility was studied for six lower extremity muscle groups in 28 subjects. The measurements were performed by one experienced and one inexperienced examiner on two separate occasions, with an interval of 1 week. The examiners were blinded to each other's and to previous results.
SETTING: University hospital.
SUBJECTS: Volunteer sample of former polio subjects.
RESULTS: For knee extension, the forces that could be measured with the HHD were limited to approximately 200N. Although the intraclass correlation coefficients were high (.75 to .98), the 95% limits of agreement between measurements showed large intervals for differences between two measurements (ratio intervals ranging from .76-1.52 to .52-2.77). The intraexaminer reproducibility for the experienced examiner was superior to that of the inexperienced examiner. The reproducibility of the inexperienced examiner showed systematic bias, with significantly higher strength values for the second session measurement of three muscle groups.
CONCLUSION: The device has good validity in the lower force range. However, because the agreement between measurements was poor, it has limited ability to detect a change in muscle strength. Therefore, this method is unable to detect small changes in lower extremity muscle strength in former polio patients.

Entities:  

Mesh:

Year:  1999        PMID: 10527094     DOI: 10.1016/s0003-9993(99)90036-9

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  9 in total

1.  Adequacy of belt-stabilized testing of knee extension strength.

Authors:  Richard W Bohannon; Deborah J Bubela; Ying-Chih Wang; Susan R Magasi; Richard C Gershon
Journal:  J Strength Cond Res       Date:  2011-07       Impact factor: 3.775

2.  Effects of underwater treadmill training on leg strength, balance, and walking performance in adults with incomplete spinal cord injury.

Authors:  Sandra L Stevens; Jennifer L Caputo; Dana K Fuller; Don W Morgan
Journal:  J Spinal Cord Med       Date:  2014-06-26       Impact factor: 1.985

3.  Leg strength, preferred walking speed, and daily step activity in adults with incomplete spinal cord injuries.

Authors:  Sandra L Stevens; Dana K Fuller; Don W Morgan
Journal:  Top Spinal Cord Inj Rehabil       Date:  2013

4.  Use of hand-held dynamometry in the evaluation of lower limb muscle strength in people with Huntington's disease.

Authors:  Monica E Busse; Gareth Hughes; Charles M Wiles; Anne E Rosser
Journal:  J Neurol       Date:  2008-08-02       Impact factor: 4.849

5.  Smoking and Early COPD as Independent Predictors of Body Composition, Exercise Capacity, and Health Status.

Authors:  Laura Miranda de Oliveira Caram; Renata Ferrari; André Luís Bertani; Thaís Garcia; Carolina Bonfanti Mesquita; Caroline Knaut; Suzana Erico Tanni; Irma Godoy
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

6.  Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

Authors:  Naoko Ushiyama; Yasushi Kurobe; Kimito Momose
Journal:  J Phys Ther Sci       Date:  2017-11-24

7.  Reliability of lower extremity muscle strength measurements with handheld dynamometry in stroke patients during the acute phase: a pilot reliability study.

Authors:  Hsiao-Ching Yen; Jer-Junn Luh; Ting Teng; Guan-Shuo Pan; Wen-Shiang Chen; Chiang-Chang Hsun; Jiann-Shing Jeng
Journal:  J Phys Ther Sci       Date:  2017-02-24

8.  Whole Body Vibration Methods with Survivors of Polio.

Authors:  Carolyn P Da Silva
Journal:  J Vis Exp       Date:  2018-10-17       Impact factor: 1.355

9.  Hand-held dynamometry in patients with haematological malignancies: measurement error in the clinical assessment of knee extension strength.

Authors:  Ruud H Knols; Geert Aufdemkampe; Eling D de Bruin; Daniel Uebelhart; Neil K Aaronson
Journal:  BMC Musculoskelet Disord       Date:  2009-03-09       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.