Bursting strength evaluation after different types of mesh fixation in laparoscopic herniorrhaphy.

C Hollinsky1, S Göbl.   

Abstract

BACKGROUND: In laparoscopic inguinal herniorrhaphy, meshes commonly have been fixed with a stapler. Recently, a new mode of fixation using a helical fastener has been introduced. The purpose of this experimental study was to compare the stability achieved by various types of mesh fixation.
METHODS: In 20 human cadavers, polypropylene meshes 10 x 15 cm in size were fixed in both groins by using either a helical fastener or a hernia stapler (4.8 mm). The mesh was fixed with 2, 4, and 8 elements and stressed with a dynamometer until the prosthesis ruptured. A paired and two-sided Student's t-test was used for statistical evaluation.
RESULTS: With the helical fastener, the mesh could be fixed always at the desired site. However, with the stapler, it was not possible to fix the mesh in the pubic bone or, at times, in the Cooper's ligament. When two fixation elements were used, the mesh fixed by the helical fastener was able to withstand a median load of 34 N (range 23-53 N), and that fixed by the stapler 7.5 N (range 3-12 N; p < 0.001). When four fixation elements were used, the mesh fixed by the helical fastener was able to withstand 70.5 N (range 53-80 N) and that fixed by the stapler 17. 5 N (range 4-25 N; p < 0.001). With the use of eight elements, the mesh fixed by the helical fastener withstood 127 N (range 84-156 N) and that fixed by the stapler 32.5 N (range 15-59 N; p < 0.001). Thus, in all cases the helical fastener was significantly more stress resistant. The main reason for detachment of the mesh was tissue disruption or deformation of the fixation elements. Only when a stress of more than 130 N was applied did the mesh tear in two cases.
CONCLUSIONS: The stress-bearing capacity (shear force resistance) of a mesh fixed by a helical fastener is up to four times that of a mesh fixed by a stapler. Therefore, the helical fastener provides significantly more stable fixation and will be able to protect the patient better from recurrent hernias caused by mesh migration.

Entities:  

Mesh:

Year:  1999        PMID: 10526026     DOI: 10.1007/s004649901146

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  17 in total

1.  Acute tensile strength analysis of collagen solder for mesh fixation to the peritoneal surface.

Authors:  R J Lanzafame; B A Soltz; I Stadler; M A Soltz; R Soltz; D P DeVore
Journal:  Surg Endosc       Date:  2004-12-09       Impact factor: 4.584

Review 2.  Laparoscopic hernia repair--TAPP or/and TEP?

Authors:  B J Leibl; C Jäger; B Kraft; K Kraft; J Schwarz; M Ulrich; R Bittner
Journal:  Langenbecks Arch Surg       Date:  2005-02-15       Impact factor: 3.445

3.  Small bowel obstruction and perforation due to a displaced spiral tacker: a rare complication of laparoscopic inguinal hernia repair.

Authors:  G Peach; L C Tan
Journal:  Hernia       Date:  2007-11-20       Impact factor: 4.739

4.  Recurrence following endoscopic extraperitoneal inguinal hernioplasty.

Authors:  H Lau
Journal:  Hernia       Date:  2007-07-03       Impact factor: 4.739

5.  Tensile strength testing for resorbable mesh fixation systems in laparoscopic ventral hernia repair.

Authors:  Emmelie Reynvoet; Frederik Berrevoet; Filip De Somer; Griet Vercauteren; Ingrid Vanoverbeke; Koen Chiers; Roberto Troisi
Journal:  Surg Endosc       Date:  2012-04-05       Impact factor: 4.584

Review 6.  Evidence-based assessment of the period of physical inactivity required after inguinal herniotomy.

Authors:  Hartmut Buhck; Mireille Untied; Wolf O Bechstein
Journal:  Langenbecks Arch Surg       Date:  2012-09-30       Impact factor: 3.445

7.  Are postoperative complaints and complications influenced by different techniques in fashioning and fixing the mesh in transperitoneal laparoscopic hernioplasty? Results of a prospective randomized trial.

Authors:  Bernhard J Leibl; Barbara Kraft; Jens Daniel Redecke; Claus Georg Schmedt; Martin Ulrich; Klaus Kraft; Reinhard Bittner
Journal:  World J Surg       Date:  2002-09-26       Impact factor: 3.352

8.  Objective hypoesthesia and pain after transabdominal preperitoneal hernioplasty: a prospective, randomized study comparing tissue adhesive versus spiral tacks.

Authors:  Lukas Brügger; Martina Bloesch; Ramin Ipaktchi; Anita Kurmann; Daniel Candinas; Guido Beldi
Journal:  Surg Endosc       Date:  2011-11-02       Impact factor: 4.584

9.  Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial.

Authors:  Hung Lau
Journal:  Ann Surg       Date:  2005-11       Impact factor: 12.969

10.  Mesh fixation in TAPP laparoscopic hernia repair: introduction of a new method in a prospective randomized trial.

Authors:  Behrooz Kleidari; Mohsen Mahmoudieh; Mohammad Yaribakht; Zhila Homaei
Journal:  Surg Endosc       Date:  2013-10-03       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.