Literature DB >> 10525699

Comparison of polylactide screw and expansion bolt in bioabsorbable fixation with patellar tendon bone graft for anterior cruciate ligament rupture of the knee. A preliminary study.

P Tuompo1, E K Partio, K Jukkala-Partio, T Pohjonen, P Helevirta, P Rokkanen.   

Abstract

In a preliminary study, 24 patients with rupture of the anterior cruciate ligament (ACL) were operated on using implants made of self-reinforced poly-l-lactide (SR-PLLA). The operation method was outside-in bone-tendon-bone reconstruction. In 10 patients the fixation was made with an SR-PLLA screw with a diameter of 6.3 mm, in 12 with an SR-PLLA expansion plug with a diameter of 6.0 mm, and in two cases both implants were used, but these cases were excluded from comparison. The purpose of the study was to evaluate and compare the use and fixation results of these two implants. The follow-up time averaged 3.2 years. Twenty patients attended follow-up. On subjective evaluations, seven of the eight patients following SR-PLLA screw fixation and six of the ten after expansion plug fixation regarded their knee as normal or nearly normal. Arthrometric testing showed the side-to-side difference to average 2. 9 mm following SR-PLLA screw fixation and 2.6 mm after expansion plug fixation (NS). Six of the patients had giving-way symptoms (two after screw fixation and four after plug fixation). The pivot shift test was slightly positive in two patients and positive in one patient after SR-PLLA screw fixation, and in three knees slightly positive and in another three knees positive following expansion plug fixation. Radiography showed variation in the location and orientation of the bone channels. Magnetic resonance imaging was performed in seven cases, and in two cases an edema was found in the tendon of the anterior cruciate ligament graft and in six cases the implants were visible. No statistical difference in results between the SR-PLLA screw and SR-PLLA expansion bolt was noted. Fixation with expansion plug seems technically more challenging, with a tendency to inferior results compared to screw fixation. In the absorbable fixation of a bone-tendon-bone graft there are no metallic artifacts on magnetic resonance imaging and no need to remove the fixation material regarding the revision surgery.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10525699     DOI: 10.1007/s001670050167

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  2 in total

1.  Fixation strength of a novel bioabsorbable expansion bolt for patellar tendon bone graft fixation: an experimental study in calf tibial bone.

Authors:  Stefan Piltz; Patrick Strunk; Ludger Meyer; Wolfgang Plitz; Guenter Lob
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-24       Impact factor: 4.342

2.  A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws.

Authors:  Jon Olav Drogset; Lene Granrud Straume; Ingrid Bjørkmo; Gunnar Myhr
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-14       Impact factor: 4.342

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.