Literature DB >> 10525491

Mechanical remodeling of the left atrium after loss of atrioventricular synchrony. A long-term study in humans.

P B Sparks1, H G Mond, J K Vohra, A G Yapanis, L E Grigg, J M Kalman.   

Abstract

BACKGROUND: Tachycardia-mediated mechanical remodeling of the atrium is considered central to the pathogenesis of thromboembolism associated with chronic atrial fibrillation. Whether atrial mechanical remodeling also occurs in response to atrial stretch induced by chronic asynchronous ventricular pacing in patients with permanent pacemakers is unknown. METHODS AND
RESULTS: The study design was a prospective randomized comparison between 21 patients paced chronically in the VVI mode and 11 patients paced chronically in the DDD mode for 3 months. Left atrial appendage (LAA) function and the presence of spontaneous echo contrast (SEC) were determined with transesophageal echocardiography (TEE) within 24 hours of pacemaker implantation and after 3 months. The VVI patients were then programmed to DDD and underwent a third TEE after DDD pacing for an additional 3 months. After chronic VVI pacing, LAA velocity decreased from 82.4+/-29.0 to 42.1+/-25.4 cm/s (P<0.01), LAA fractional area change decreased from 74.9+/-17.2% to 49.8+/-22.0% (P<0.01), and 4 patients (19%) developed left atrial SEC (P<0.05). With the reestablishment of chronic AV synchrony, LAA velocity increased to 61.6+/-18.5 cm/s (P<0.01), LAA fractional area change increased to 76.4+/-18.1% (P<0.01), and SEC resolved. In the 11 patients undergoing chronic DDD pacing, no significant changes in LAA velocity (baseline, 86.0+/-28.8 cm/s versus 3 months, 79.6+/-14. 9 cm/s) or LAA fractional area change (baseline, 76.2+/-19.4% versus 72.5+/-15.7%) were demonstrated, and SEC did not develop.
CONCLUSIONS: Chronic loss of AV synchrony induced by VVI pacing is associated with mechanical remodeling of the left atrium, which may reverse after the reestablishment of AV synchrony with DDD pacing. This process may be partly responsible for the higher incidence of thromboembolism observed in patients undergoing VVI pacing compared with AV sequential pacing.

Entities:  

Mesh:

Year:  1999        PMID: 10525491     DOI: 10.1161/01.cir.100.16.1714

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  15 in total

1.  Physiologic pacing: where pacing mode selection reflects the indication.

Authors:  J S Healey; E Crystal; S J Connolly
Journal:  Heart       Date:  2004-06       Impact factor: 5.994

2.  The search for optimal atrioventricular interval.

Authors:  I Eli Ovsyshcher
Journal:  J Interv Card Electrophysiol       Date:  2005-11       Impact factor: 1.900

Review 3.  Atrial Septal Defect and Atrial Fibrillation: The Known and Unknown.

Authors:  George E Blake; Dhanunjaya Lakkireddy
Journal:  J Atr Fibrillation       Date:  2008-09-16

Review 4.  Atrial Remodeling And Atrial Fibrillation: Mechanistic Interactions And Clinical Implications.

Authors:  Bandar Al Ghamdi; Walid Hassan
Journal:  J Atr Fibrillation       Date:  2009-06-01

5.  Left atrial remodeling index is a feasible predictor of poor prognosis in patients with acute ischemic stroke.

Authors:  Naoto Hashimoto; Tetsu Watanabe; Harutoshi Tamura; Hayato Tsuchiya; Masahiro Wanezaki; Shigehiko Kato; Satoshi Nishiyama; Takanori Arimoto; Hiroki Takahashi; Tetsuro Shishido; Masafumi Watanabe
Journal:  Heart Vessels       Date:  2019-06-05       Impact factor: 2.037

6.  DDD mode-switching and loss of atrioventricular synchrony evokes heart failure: A rare but possible trigger of pacing-induced cardiomyopathy.

Authors:  Daisetsu Aoyama; Moe Mukai; Kenichi Kaseno; Toshihiko Tsuji; Keiichi Sakakibara; Kanae Hasegawa; Minoru Nodera; Shinsuke Miyazaki; Hiroyasu Uzui; Hiroshi Tada
Journal:  J Cardiol Cases       Date:  2020-11-21

7.  [Atrial pacing for prevention of atrial fibrillation. Influence of septal atrial pacing, atrial overdrive and AV-delay-optimization on atrial fibrillation burden].

Authors:  M Klein; N Klein; D Pfeiffer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-09

8.  Effects of cardioactive medications on retrograde conduction: continuing relevance for current devices.

Authors:  John E O'Mara; John D Fisher; Sue J Goldie; Soo G Kim; Kevin J Ferrick; Jay N Gross; Eugen C Palma
Journal:  J Interv Card Electrophysiol       Date:  2006-01       Impact factor: 1.759

Review 9.  Cardiac Mechano-Gated Ion Channels and Arrhythmias.

Authors:  Rémi Peyronnet; Jeanne M Nerbonne; Peter Kohl
Journal:  Circ Res       Date:  2016-01-22       Impact factor: 17.367

Review 10.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.