Direct determination of bisphenol A and nonylphenol in river water by column-switching semi-microcolumn liquid chromatography/electrospray mass spectrometry

.   

Abstract

A rapid and sensitive analytical method based on column-switching semi-microcolumn high-performance liquid chromatography (HPLC) with electrospray mass spectrometry was developed for determining trace levels of bisphenol A (2,2-bis(4-hydroxyphenyl)propane) and nonylphenol (4-nonylphenol) in river water. An aliquot of sample solution was directly injected into the precolumn packed with Capcellpak MF-Ph for sample cleanup and enrichment. The compounds of interest were then transferred to a C-18 analytical column for main separation through a change in flow path by a programmed switching valve. Bisphenol A, nonylphenol, and interfering substances were satisfactorily separated with a simple gradient elution complete within 35 min. Detection of their deprotonated molecules was conducted in negative ion mode. A reduced flow rate (100 &mgr;L/min) optimized for the narrow bore column was found advantageous in obtaining a high degree of sensitivity during electrospray detection. The influence of carrier additives on sensitivity was also examined. This method produced detection limits of 0.5 ng/mL for bisphenol A and 10 ng/mL for nonylphenol (signal-to-noise ratio 3). Calibration curves were observed in the range of 2.5-50 ng/mL (r(2) = 0.999) for bisphenol A and 50-500 ng/mL (r(2) = 0.998) for nonylphenol. Recoveries of the compounds from spiked distilled water and river water were 99.7-138.5% with a relative standard deviation (RSD) ranging from 2.2-9.7%. Copyright 1999 John Wiley & Sons, Ltd.

Entities:  

Year:  1999        PMID: 10523782     DOI: 10.1002/(SICI)1097-0231(19991115)13:21<2204::AID-RCM776>3.0.CO;2-9

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Nitrogen-doped carbon quantum dots for fluorescence detection of Cu2+ and electrochemical monitoring of bisphenol A.

Authors:  Xinran Wu; Lina Wu; Xizhong Cao; Ying Li; Anran Liu; Songqin Liu
Journal:  RSC Adv       Date:  2018-05-30       Impact factor: 4.036

2.  Parent bisphenol A accumulation in the human maternal-fetal-placental unit.

Authors:  Gilbert Schönfelder; Werner Wittfoht; Hartmut Hopp; Chris E Talsness; Martin Paul; Ibrahim Chahoud
Journal:  Environ Health Perspect       Date:  2002-11       Impact factor: 9.031

3.  Novel Class of Isoxazole-Based Gelators for the Separation of Bisphenol A from Water and Cleanup of Oil Spills.

Authors:  Santosh Kumar Singh; Priyanka Saha; Swapan Dey; Sukhendu Nandi
Journal:  ACS Omega       Date:  2020-04-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.