Literature DB >> 10521770

Acute cerebral redistribution in response to invasive procedures in the human fetus.

J M Teixeira1, V Glover, N M Fisk.   

Abstract

OBJECTIVES: We sought to investigate the fetal hemodynamic response to the acute stress of invasive procedures. STUDY
DESIGN: The middle cerebral artery pulsatility index was measured by Doppler ultrasonography before and after 136 invasive procedures (fetal blood sampling, transfusion, shunt insertion, tissue biopsy, and ovarian cyst aspiration). The response of fetuses submitted to invasive procedures involving transgression of the fetal body, such as intrahepatic vein blood sampling, was compared with that of control procedures at the placental cord insertion.
RESULTS: The middle cerebral artery pulsatility index value fell with fetal blood sampling performed at the intrahepatic vein (median, -0.26; 95% confidence interval, -0.35 to -0.15) but not at the placental cord insertion (median, 0.05; 95% confidence interval, -0.04 to 0.19). With transfusions, the middle cerebral artery pulsatility index also fell with procedures at the intrahepatic vein (mean, -0.51; 95% confidence interval, -0.66 to -0.35) but not at the placental cord insertion (mean, -0.04; 95% confidence interval, -0.23 to 0.14). The magnitude of the response was greater with transfusions than with blood sampling alone. The middle cerebral artery pulsatility index value also fell with non-fetal blood sampling procedures involving transgression of the fetal body (mean, -0.32; 95% confidence interval, -0.56 to -0.09) but not with control non-fetal blood sampling procedures. The change in the middle cerebral artery pulsatility index was not related to gestational age, with the youngest fetus showing a fall in the middle cerebral artery pulsatility index value being at 16 weeks' gestation. Although the degree of response was weakly correlated with the duration of needling (y = -0.21 - 0.00014x; R (2) = 0.08; P =.02), multiple logistic regression demonstrated that this was instead a function of the type of the procedure. A response was seen within 70 seconds of fetal puncture. The fetal heart rate did not change significantly with procedures in any of the above-mentioned groups.
CONCLUSIONS: The human fetus mounts a cerebral hemodynamic response to invasive procedures involving transgression of the fetal body, which is consistent with the brain-sparing effect.

Entities:  

Mesh:

Year:  1999        PMID: 10521770     DOI: 10.1016/s0002-9378(99)70340-6

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  4 in total

Review 1.  Anesthesia for myelomeningocele surgery in fetus.

Authors:  Juan Carlos Devoto; Juan Luis Alcalde; Felipe Otayza; Waldo Sepulveda
Journal:  Childs Nerv Syst       Date:  2017-05-25       Impact factor: 1.475

2.  Human fetal and maternal corticotrophin releasing hormone responses to acute stress.

Authors:  R Gitau; N M Fisk; V Glover
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-01       Impact factor: 5.747

Review 3.  Plasticity of GABAA Receptors during Pregnancy and Postpartum Period: From Gene to Function.

Authors:  Valentina Licheri; Giuseppe Talani; Ashish A Gorule; Maria Cristina Mostallino; Giovanni Biggio; Enrico Sanna
Journal:  Neural Plast       Date:  2015-08-30       Impact factor: 3.599

4.  Fetal Pain in the First Trimester.

Authors:  Bridget Thill
Journal:  Linacre Q       Date:  2021-12-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.