Literature DB >> 10521623

Biomechanical properties of muscle-tendon unit under high-speed passive stretch.

R Lin1, G Chang, L Chang.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the strain injury mechanisms of the Achilles muscle-tendon unit during high-speed passive stretch.
DESIGN: The high-speed traction device consisted of an impactor which dropped freely to hit one end of a lever, transferring the impact energy to traction energy at the other end. A muscle-tendon unit was attached to the other end of the lever via a force link, and the elongation was recorded with a high-speed camera.
BACKGROUND: The muscle-tendon unit is thought to act viscoelastically. It is generally strain rate dependent, exhibiting higher tensile stress at faster strain rates. However, previous studies of passive stretch in muscle-tendon units usually employed low strain rates.
METHODS: 16 fresh Achilles muscle-tendon units were subjected to passive stretch at a test speed of 310 cm s(-1). The history of elongation and the traction force of the muscle-tendon unit during the elongation process were analyzed.
RESULTS: The muscle-tendon units exhibited highly nonlinear mechanical behavior. Most of the elongation occurred in muscle and resulted in structural failure. Failure was not found in the tendon or muscle-tendon junction. Muscle fibers during stretching reached their maximum mechanical strength and then progressively ruptured.
CONCLUSION: The strain rate is an important factor in strain injuries of the muscle-tendon unit due to passive stretch. The muscle is a good energy absorber; the rupture process can absorb a great deal of external energy and prevent complete failure of the muscle, while also protecting bone and joints. RELEVANCE: The study of muscle-tendon unit under high-speed stretch could help us to understand the mechanism of strain injuries over passive stretch in real-life situations.

Entities:  

Mesh:

Year:  1999        PMID: 10521623     DOI: 10.1016/s0268-0033(98)00108-9

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  Transversely isotropic tensile material properties of skeletal muscle tissue.

Authors:  Duane A Morrow; Tammy L Haut Donahue; Gregory M Odegard; Kenton R Kaufman
Journal:  J Mech Behav Biomed Mater       Date:  2009-04-05

2.  Biomechanical analyses of the efficacy of patterns of maternal effort on second-stage progress.

Authors:  Kuo-Cheng Lien; John O L DeLancey; James A Ashton-Miller
Journal:  Obstet Gynecol       Date:  2009-04       Impact factor: 7.661

3.  The effect of strain and age on the mechanical properties of rat Achilles tendons.

Authors:  Emily C Vafek; Johannes F Plate; Eric Friedman; Sandeep Mannava; Aaron T Scott; Kerry A Danelson
Journal:  Muscles Ligaments Tendons J       Date:  2018-01-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.