Literature DB >> 10520812

Validation of a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve: comparison with intracoronary Doppler flow wire.

C Caiati1, C Montaldo, N Zedda, R Montisci, M Ruscazio, G Lai, M Cadeddu, L Meloni, S Iliceto.   

Abstract

OBJECTIVES: We tested the hypothesis that coronary flow reserve (CFR) in the left anterior descending coronary artery (LAD) as assessed by a new noninvasive method (contrast-enhanced transthoracic second harmonic echo Doppler) is in agreement with CFR measurements assessed by intracoronary Doppler flow wire.
BACKGROUND: Contrast-enhanced transthoracic second harmonic echo Doppler is a novel noninvasive method to detect blood flow velocity and reserve in the LAD. However, it has not yet been validated versus a gold-standard method.
METHODS: Twenty-five patients undergoing CFR assessment in the LAD by Doppler flow wire were also evaluated by contrast-enhanced transthoracic Doppler to record blood flow in the distal LAD at rest and during hyperemia obtained by adenosine i.v. infusion. In five patients CFR was evaluated twice (before and after angioplasty).
RESULTS: As a result of the combined use of i.v. contrast and second harmonic Doppler technology, feasibility in assessing coronary flow reserve equaled 100%. The agreement between the two methods was high. In fact, in all but five patients the maximum difference between the two CFR measurements was 0.38. Overall, the prediction (95%) interval of individual differences was -0.69 to +0.72. Reproducibility of CFR measurements was also high. The limits of the agreement (95%) between the two measurements were -0.32 to +0.32.
CONCLUSIONS: Coronary flow reserve in the LAD as assessed by contrast-enhanced transthoracic echo Doppler along with harmonic mode concurs very closely with Doppler flow wire CFR measurements. This new noninvasive method allows feasible, reliable and reproducible assessment of CFR in the LAD.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10520812     DOI: 10.1016/s0735-1097(99)00342-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  52 in total

Review 1.  Emergence of Nonobstructive Coronary Artery Disease: A Woman's Problem and Need for Change in Definition on Angiography.

Authors:  Carl J Pepine; Keith C Ferdinand; Leslee J Shaw; Kelly Ann Light-McGroary; Rashmee U Shah; Martha Gulati; Claire Duvernoy; Mary Norine Walsh; C Noel Bairey Merz
Journal:  J Am Coll Cardiol       Date:  2015-10-27       Impact factor: 24.094

2.  Value of the myocardial performance index in myocardial infarction.

Authors:  L Galiuto
Journal:  Heart       Date:  2005-05       Impact factor: 5.994

3.  Non-invasive coronary flow reserve is correlated with microvascular integrity and myocardial viability after primary angioplasty in acute myocardial infarction.

Authors:  R Montisci; L Chen; M Ruscazio; P Colonna; C Cadeddu; C Caiati; M Montisci; L Meloni; S Iliceto
Journal:  Heart       Date:  2006-01-31       Impact factor: 5.994

4.  Coronary flow velocity changes in response to hypercapnia: assessment by transthoracic Doppler echocardiography.

Authors:  Wendy S Tzou; Claudia E Korcarz; Susan E Aeschlimann; Barbara J Morgan; James B Skatrud; James H Stein
Journal:  J Am Soc Echocardiogr       Date:  2007-04       Impact factor: 5.251

5.  Possible further reduction in coronary flow velocity reserve in angina pectoris patients after oral glucose loading.

Authors:  Hidetoshi Yoshitani; Masaaki Takeuchi; Yutaka Otsuji; Takashi Akasaka; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2013-01-22

Review 6.  Coronary microvascular dysfunction: mechanisms and functional assessment.

Authors:  Paolo G Camici; Giulia d'Amati; Ornella Rimoldi
Journal:  Nat Rev Cardiol       Date:  2014-10-14       Impact factor: 32.419

7.  The physiologic evaluation of stenosis by transthoracic Doppler: a bit of theory, a lot of practice.

Authors:  Jonathan R Lindner
Journal:  J Am Soc Echocardiogr       Date:  2011-04       Impact factor: 5.251

Review 8.  Women with Stable Angina Pectoris and No Obstructive Coronary Artery Disease: Closer to a Diagnosis.

Authors:  Marie Mide Michelsen; Naja Dam Mygind; Daria Frestad; Eva Prescott
Journal:  Eur Cardiol       Date:  2017-08

9.  Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio, and non-invasive coronary flow reserve.

Authors:  P Meimoun; J Clerc; D Ardourel; U Djou; S Martis; T Botoro; F Elmkies; H Zemir; A Luycx-Bore; J Boulanger
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-17       Impact factor: 2.357

Review 10.  Coronary microvasculopathy in heart transplantation: Consequences and therapeutic implications.

Authors:  Alessandra Vecchiati; Sara Tellatin; Annalisa Angelini; Sabino Iliceto; Francesco Tona
Journal:  World J Transplant       Date:  2014-06-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.