Literature DB >> 10520792

Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: results of a meta-analysis of the BElgian NEtherlands Stent study (BENESTENT) I, BENESTENT II Pilot, BENESTENT II and MUSIC trials. Multicenter Ultrasound Stent In Coronaries.

P W Serruys1, I P Kay, C Disco, N V Deshpande, P J de Feyter.   

Abstract

OBJECTIVES: We aimed to identify periprocedural quantitative coronary angiographic (QCA) variables that have predictive value on long-term angiographic results and to construct multivariate models using these variables for postprocedural prognosis.
BACKGROUND: Coronary stent implantation has reduced the restenosis rate significantly as compared with balloon angioplasty in short de novo lesions in coronary arteries >3 mm in size. Although the postprocedural minimal luminal diameter (MLD) is known to have significant bearing on long-term angiographic results, no practically useful model exists for prediction of angiographic outcome based on the periprocedural QCA variables.
METHODS: The QCA data from patients who underwent Palmaz-Schatz stent implantation for short (<15 mm) de novo lesions in coronary arteries >3 mm and completed six months of angiographic follow-up in the four prospective clinical trials (BENESTENT I, BENESTENT II pilot, BENESTENT II and MUSIC) were pooled. Multiple models were constructed using multivariate analysis. The Hosmer-Lemeshow goodness-of-fit test was used to identify the model of best fit, and this model was used to construct a reference chart for prediction of angiographic outcome on the basis of periprocedural QCA variables.
RESULTS: Univariate analysis performed using QCA variables revealed that vessel size, MLD before and after the procedure, reference area before and after the procedure, minimal luminal cross-sectional area before and after the procedure, diameter stenosis after the procedure, area of plaque after the procedure and area stenosis after the procedure were significant predictors of angiographic outcome. Using multivariate analysis, the Hosmer-Lemeshow goodness-of-fit test showed that the model containing percent diameter stenosis after the procedure and vessel size best fit the data. A reference chart was then developed to calculate the expected restenosis rate.
CONCLUSIONS: Restenosis rate after stent implantation for short lesions can be predicted using the variables percent diameter stenosis after the procedure and vessel size. This meta-analysis indicates that the concept of "the bigger the better" holds true for coronary stent implantation. Applicability of the model beyond short lesions should be tested.

Entities:  

Mesh:

Year:  1999        PMID: 10520792     DOI: 10.1016/s0735-1097(99)00308-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  15 in total

1.  Drug eluting stents: maximising benefit and minimising cost.

Authors:  J Gunn; A C Morton; C Wales; C M H Newman; D C Crossman; D C Cumberland
Journal:  Heart       Date:  2003-02       Impact factor: 5.994

Review 2.  Current understanding of coronary in-stent restenosis. Pathophysiology, clinical presentation, diagnostic work-up, and management.

Authors:  T M Schiele
Journal:  Z Kardiol       Date:  2005-11

3.  Contemporary Use of Drug-eluting Stents.

Authors:  William W Chu; Ron Waksman
Journal:  Curr Treat Options Cardiovasc Med       Date:  2005-05

4.  The Sirolimus-eluting coronary stent in daily routine practice in Germany: trends in indications over the years. Results from the prospective multi-centre German Cypher Stent Registry.

Authors:  Ralf Zahn; C W Hamm; S Schneider; U Zeymer; G Richardt; M Kelm; B Levenson; T Bonzel; U Tebbe; G Sabin; C A Nienaber; Thomas Pfannebecker; J Senges
Journal:  Clin Res Cardiol       Date:  2007-06-04       Impact factor: 5.460

5.  Hyperexpansion of coronary stents and clinical outcomes.

Authors:  Alexandre Schaan de Quadros; Rogério Sarmento-Leite; Carlos A M Gottschall; Guilherme V Silva; Emerson C Perin
Journal:  Tex Heart Inst J       Date:  2006

Review 6.  Small coronary vessel angioplasty: outcomes and technical considerations.

Authors:  Sudhir Rathore
Journal:  Vasc Health Risk Manag       Date:  2010-10-21

Review 7.  Drug-eluting stents: new era and new concerns.

Authors:  V Bhatia; R Bhatia; M Dhindsa
Journal:  Postgrad Med J       Date:  2004-01       Impact factor: 2.401

8.  Combining short stent implantation and drug-eluting stenting for routine use yields a low restenosis rate.

Authors:  Ulrich Dietz; Cheryl Dauer; Heinz Lambertz
Journal:  Exp Clin Cardiol       Date:  2006

9.  Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials.

Authors:  Lucas Lodi-Junqueira; Marcos Roberto de Sousa; Leonardo Carvalho da Paixão; Silvana Márcia Bruschi Kelles; Carlos Faria Santos Amaral; Antonio L Ribeiro
Journal:  Syst Rev       Date:  2012-09-21

Review 10.  Update on stents: recent studies on the TAXUS stent system in small vessels.

Authors:  Shuzou Tanimoto; Joost Daemen; Patrick W Serruys
Journal:  Vasc Health Risk Manag       Date:  2007
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.