Literature DB >> 10515463

Quantitation of benzodiazepine receptor binding with PET [11C]iomazenil and SPECT [123I]iomazenil: preliminary results of a direct comparison in healthy human subjects.

J D Bremner1, R Baldwin, A Horti, L H Staib, C K Ng, P Z Tan, Y Zea-Ponce, S Zoghbi, J P Seibyl, R Soufer, D S Charney, R B Innis.   

Abstract

Although positron emission tomography (PET) and single photon emission computed tomography (SPECT) are increasingly used for quantitation of neuroreceptor binding, almost no studies to date have involved a direct comparison of the two. One study found a high level of agreement between the two techniques, although there was a systematic 30% increase in measures of benzodiazepine receptor binding in SPECT compared with PET. The purpose of the current study was to directly compare quantitation of benzodiazepine receptor binding in the same human subjects using PET and SPECT with high specific activity [11C]iomazenil and [123I]iomazenil, respectively. All subjects were administered a single bolus of high specific activity iomazenil labeled with 11C or 123I followed by dynamic PET or SPECT imaging of the brain. Arterial blood samples were obtained for measurement of metabolite-corrected radioligand in plasma. Compartmental modeling was used to fit values for kinetic rate constants of transfer of radioligand between plasma and brain compartments. These values were used for calculation of binding potential (BP = Bmax/Kd) and product of BP and the fraction of free non-protein-bound parent compound (V3'). Mean values for V3' in PET and SPECT were as follows: temporal cortex 23+/-5 and 22+/-3 ml/g, frontal cortex23+/-6 and 22+/-3 ml/g, occipital cortex 28+/-3 and 31+/-5 ml/g, and striatum 4+/-4 and 7+/-4 ml/g. These preliminary findings indicate that PET and SPECT provide comparable results in quantitation of neuroreceptor binding in the human brain.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10515463     DOI: 10.1016/s0925-4927(99)00015-3

Source DB:  PubMed          Journal:  Psychiatry Res        ISSN: 0165-1781            Impact factor:   3.222


  5 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  Comparison of 18F PET and 99mTc SPECT imaging in phantoms and in tumored mice.

Authors:  Dengfeng Cheng; Yi Wang; Xinrong Liu; P Hendrik Pretorius; Minmin Liang; Mary Rusckowski; Donald J Hnatowich
Journal:  Bioconjug Chem       Date:  2010-08-18       Impact factor: 4.774

3.  Tobacco smoking interferes with GABAA receptor neuroadaptations during prolonged alcohol withdrawal.

Authors:  Kelly P Cosgrove; Reese McKay; Irina Esterlis; Tracy Kloczynski; Evgenia Perkins; Frederic Bois; Brian Pittman; Jack Lancaster; David C Glahn; Stephanie O'Malley; Richard E Carson; John H Krystal
Journal:  Proc Natl Acad Sci U S A       Date:  2014-12-01       Impact factor: 11.205

Review 4.  Imaging receptor changes in human drug abusers.

Authors:  Kelly P Cosgrove
Journal:  Curr Top Behav Neurosci       Date:  2010

Review 5.  Drug Development in Alzheimer's Disease: The Contribution of PET and SPECT.

Authors:  Lieven D Declercq; Rik Vandenberghe; Koen Van Laere; Alfons Verbruggen; Guy Bormans
Journal:  Front Pharmacol       Date:  2016-03-31       Impact factor: 5.810

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.