Literature DB >> 10515144

Comparison of shear bond strength of three bonding agents with metal and ceramic brackets.

B Haydar1, S Sarikaya, Z C Cehreli.   

Abstract

Shear bond strengths of a light-cured composite resin, a light-cured glass ionomer cement, and a light-cured compomer used with metal and ceramic brackets were compared, and ARI scores were evaluated. Ceramic brackets showed statistically higher shear bond strengths than metal brackets when bonded with all test materials (p<0.001). When used with metal brackets, the light-cured glass ionomer cement (LCGIC) and compomer materials demonstrated statistically lower shear bond strengths than the light-cured composite (p<0.01 and p<0.001, respectively). When used with ceramic brackets, LCGIC was found to have significantly lower shear bond strength than the composite material (p<0.001). Despite its relatively low shear bond strength, LCGIC demonstrated optimal bonding values (8.39+/-3.24 MPa) with ceramic brackets. Bond failures within the LCGIC groups occurred at the adhesive-tooth interface, whereas in the compomer and composite groups, failures were detected at the adhesive-bracket interface. In the metal bracket group, clinically acceptable shear bond strength was obtained only with the composite resin (7.06+/-1.65 MPa). Compomer and LCGIC demonstrated values well below the accepted standard for metal brackets (4.32+/-1.75 MPa and 4.45+/-1.06, respectively), while in the ceramic bracket group, values for composite and compomer were above the desired level (14.40+/-5.88 MPa and 12.31+/-6.09, respectively). LCGIC showed reasonably good bond strength with ceramic brackets, suggesting that this material may be considered suitable for use with ceramic brackets in clinical situations where moisture cannot be controlled.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10515144     DOI: 10.1043/0003-3219(1999)069<0457:COSBSO>2.3.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  4 in total

1.  Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis.

Authors:  Spyridon N Papageorgiou; Ludger Keilig; Istabrak Hasan; Andreas Jäger; Christoph Bourauel
Journal:  Eur J Orthod       Date:  2015-07-14       Impact factor: 3.075

2.  Bond strengths of brackets bonded to enamel surfaces conditioned with femtosecond and Er:YAG laser systems.

Authors:  Cahide Aglarci; Necla Demir; Sertac Aksakalli; Erhan Dilber; Ozlem Akinci Sozer; Hamdi Sukur Kilic
Journal:  Lasers Med Sci       Date:  2016-05-25       Impact factor: 3.161

3.  Comparison of Shear Bond Strength of RMGI and Composite Resin for Orthodontic Bracket Bonding.

Authors:  Soghra Yassaei; Abdolrahim Davari; Mahjobeh Goldani Moghadam; Ahmad Kamaei
Journal:  J Dent (Tehran)       Date:  2014-05-31

4.  A Clinical Comparison of Failure Rates of Metallic and Ceramic Brackets: A Twelve-Month Study.

Authors:  Tomasz Ogiński; Beata Kawala; Marcin Mikulewicz; Joanna Antoszewska-Smith
Journal:  Biomed Res Int       Date:  2020-01-10       Impact factor: 3.411