Literature DB >> 10512965

Topographical characteristics and shear bond strength of tooth surfaces cut with a laser-powered hydrokinetic system.

S Lin1, A A Caputo, L R Eversole, I Rizoiu.   

Abstract

STATEMENT OF PROBLEM: Erbium lasers, specifically Er;YAG and Er, Cr;YSGG that emit in the near red wavelengths, cut both enamel and dentine. Bonding to these cut surfaces with composites has not been assessed for all laser systems.
PURPOSE: This investigation assessed the shear bond strength of composite bonded to tooth structure treated with an Er,Cr;YSGG-powered hydrokinetic system (HKS, Millennium system) and then was compared with surfaces treated with a carbide bur.
MATERIAL AND METHODS: Extracted human molars were cut into enamel and dentin with both systems. Nonetched and acid-etched subgroups were evaluated. Shear bond strength was measured with an Instron test machine with a knife-edge loading head. In addition, SEMs were evaluated.
RESULTS: There were no significant differences in shear bond strength between etched bur cut (23.3 +/- 2.5 MPa), etched laser-cut enamel (23.7 +/- 4.5 MPa), and nonetched laser-cut enamel (20.5 +/- 2.8 MPa). For nonetched enamel, bond strength values for laser-cut surfaces were significantly higher than the bur-cut surfaces (8.7 +/- 4.3 MPa). Bond strength differences for dentin between bur (14.3 +/- 1.7 MPa) and laser cuts (11.5 +/- 4.3 MPa) were not significant (P =.03). SEM revealed that laser cutting of enamel did not cause formation of a smear layer.
CONCLUSION: There were no significant differences in shear bond strength between etched bur-cut, etched laser-cut, and nonetched laser-cut enamel. With nonetched enamel, bond strength values for nonetched laser-cut surfaces were significantly higher than for the bur-cut surfaces. No bond strength differences between bur and laser cutting existed for dentin. Similar topography was observed for bur and laser prepared surfaces of etched enamel and nonetched dentin.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10512965     DOI: 10.1016/s0022-3913(99)70033-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  28 in total

1.  An analysis of the shear strength of the bond between enamel and porcelain laminate veneers with different etching systems: acid and Er,Cr:YSGG laser separately and combined.

Authors:  Berivan Dundar; Kahraman Gündüz Guzel
Journal:  Lasers Med Sci       Date:  2010-08-21       Impact factor: 3.161

2.  Influence of different Er,Cr:YSGG laser parameters on long-term dentin bond strength of self-etch adhesive.

Authors:  Tahsin Yildirim; Muhammet Kerim Ayar; Cemal Yesilyurt
Journal:  Lasers Med Sci       Date:  2015-10-24       Impact factor: 3.161

3.  Comparative Evaluation of the Etching Pattern of Er,Cr:YSGG & Acid Etching on Extracted Human Teeth-An ESEM Analysis.

Authors:  Rashmi Issar; Dibyendu Mazumdar; Shashi Ranjan; Naveen Kumar Krishna; Ravindra Kole; Priyankar Singh; Deirimika Lakiang; Chiranjeevi Jayam
Journal:  J Clin Diagn Res       Date:  2016-05-01

4.  Effect of different power parameters of Er,Cr:YSGG laser on human dentine.

Authors:  Piyanart Ekworapoj; Sharanbir K Sidhu; John F McCabe
Journal:  Lasers Med Sci       Date:  2007-01-23       Impact factor: 3.161

5.  Adhesion after erbium, chromium:yttrium-scandium-gallium-garnet laser application at three different irradiation conditions.

Authors:  Sérgio Brossi Botta; Patricia Aparecida da Ana; Denise Maria Zezell; John M Powers; Adriana Bona Matos
Journal:  Lasers Med Sci       Date:  2007-11-20       Impact factor: 3.161

6.  Acid-etch interval and shear bond strength of Er,Cr:YSGG laser-prepared enamel and dentin.

Authors:  Ali Obeidi; Perng-Ru Liu; Lance C Ramp; Preston Beck; Norbert Gutknecht
Journal:  Lasers Med Sci       Date:  2009-03-14       Impact factor: 3.161

7.  Influence of etching with erbium, chromium:yttrium-scandium-gallium-garnet laser on microleakage of class V restoration.

Authors:  Juliana Marotti; Vinícius Rangel Geraldo-Martins; Marina Stella Bello-Silva; Carlos de Paula Eduardo; Christian Apel; Norbert Gutknecht
Journal:  Lasers Med Sci       Date:  2008-11-15       Impact factor: 3.161

8.  Shear bond strength of composite bonded to erbium:yttrium-aluminum-garnet laser-prepared dentin.

Authors:  Sevil Gurgan; Arlin Kiremitci; Filiz Yalcin Cakir; Esra Yazici; Jale Gorucu; Norbert Gutknecht
Journal:  Lasers Med Sci       Date:  2007-12-12       Impact factor: 3.161

9.  Dental ablation with 1064 nm, 500 ps, Diode pumped solid state laser: A preliminary study.

Authors:  Michele Sozzi; Carlo Fornaini; Annamaria Cucinotta; Elisabetta Merigo; Paolo Vescovi; Stefano Selleri
Journal:  Laser Ther       Date:  2013

10.  Evaluation of mineral content of dentin prepared by erbium, chromium:yttrium scandium gallium garnet laser.

Authors:  Asli Secilmis; Subutayhan Altintas; Aslihan Usumez; Gizem Berk
Journal:  Lasers Med Sci       Date:  2007-10-20       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.