Literature DB >> 10511653

Noninvasive assessment of left and right internal mammary artery graft patency with high-frequency transthoracic echocardiography.

L De Simone1, P Caso, S Severino, M Scherillo, A D'Andrea, A Varricchio, R Violini, N Mininni.   

Abstract

OBJECTIVES: The aim of this study was (1) to visualize internal mammary artery grafts (IMAG) on coronary artery by transthoracic echocardiography and (2) to assess the patency of the grafts.
METHODS: Twenty-three patients (21 men, 56 +/- 6 years) with previous coronary artery bypass grafting were studied at baseline and after they underwent low-dose dipyridamole infusion. The parameters obtained were systolic (SPV) and diastolic (DPV) peak velocities and their ratio (DPV/SPV); the dipyridamole infusion to baseline ratio of DPV was an index of IMAG blood flow reserve (FR). Two groups of patients were selected at baseline: group A, (n = 12) with a DPV/SPV >1, and group B (n = 11), with a DPV/SPV <1.
RESULTS: The IMAG was identified in all patients. Intraluminal flow signals obtained with pulsed wave Doppler showed a biphasic pattern (1 systolic and 1 diastolic wave). After dipyridamole infusion was administered, flow velocities increased in 11 of 12 patients in group A and in 5 of 11 patients in group B. In group A the DPV/SPV increased from 1.79 +/- 0.47 to 1.8 +/- 0.43 (P = not significant), and the FR was 1.8 +/- 0.4. In group B the DPV/SPV increased from 0. 46 +/- 0.05 to 0.5 +/- 0.09 (P = not significant), and the FR was 1. 3 +/- 0.41. Coronary angiography showed the graft patency in all patients in group A and in 5 patients in group B with increased flow velocity after dipyridamole infusion. In the identification of graft stenosis at baseline, DPV/SPV showed 100% sensibility and 58% specificity, and FR showed 92% sensibility and 84% specificity.
CONCLUSION: Doppler echocardiographic evaluation of the IMAG is a simple noninvasive method to assess the functional impairment of the vessel.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10511653     DOI: 10.1016/s0894-7317(99)70189-6

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  5 in total

1.  Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography.

Authors:  F Chirillo; A Bruni; G Balestra; C Cavallini; Z Olivari; J D Thomas; P Stritoni
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

2.  Effects of previously well-developed collateral vessels on left internal mammary artery graft flow after bypass surgery.

Authors:  Ozcan Ozdemir; Deniz Ozdemirel Ozkan; Mustafa Soylu; Ahmet Duran Demir; Omer Alyan; Bilal Geyik; Dursun Aras; Aysegul Kunt; Kemal Arda; Hatice Sasmaz; Adnan Cobanoglu
Journal:  Tex Heart Inst J       Date:  2005

3.  Recovery of distal coronary flow reserve in LAD and LCx after Y-Graft intervention assessed by transthoracic echocardiography.

Authors:  Antonio Auriti; Vincenzo Loiaconi; Christian Pristipino; Francesco Saverio Leonardi Cattolica; Roberto Cini; Vincenzo Guido; Cinzia Cianfrocca; Salvatore Greco; Filomena Agostini; Mario Staibano; Massimo Santini
Journal:  Cardiovasc Ultrasound       Date:  2010-08-17       Impact factor: 2.062

4.  Colour Doppler ultrasonography for evaluation of anterior chest blood supply: the possible role of arterial blood supply to the costosternal junction in the aetiology of idiopathic scoliosis in female adolescents.

Authors:  Panagiotis Korovessis; Panagiotis Iliopoulos; Alexandros Misiris; Georgios Koureas
Journal:  Eur Spine J       Date:  2003-11-28       Impact factor: 3.134

Review 5.  Transthoracic Doppler echocardiography - noninvasive diagnostic window for coronary flow reserve assessment.

Authors:  Paweł Petkow Dimitrow
Journal:  Cardiovasc Ultrasound       Date:  2003-04-11       Impact factor: 2.062

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.