Literature DB >> 10510516

Evaluation of hand and finger heat loss with a heated hand model.

F Chen1, H Nilsson, I Holmér.   

Abstract

A heated full-scale hand model has been used to determine indirectly hand and finger heat losses of human subjects exposed to four ambient cold conditions (0, 4, 10 and 16 degrees C, air velocity approximately 0.3 m/s). Heat transfer coefficients determined with the hand model, were used to calculate heat flux based on measured skin to ambient temperature gradients. The responses of eight subjects from a previous study were used for the analysis. The measurements were carried out in a small climate chamber which was cooled by evaporating liquid carbon dioxide. The thermal hand was put into the chamber in a vertical position with the thumb up. The surface temperature of the thermal hand was controlled at 21, 25, 28, 31 and 34 degrees C under each of the four ambient cold conditions, in order to investigate possible temperature dependence of the calculated combined convective and radiate heat transfer coefficient (hCR). The value of hCR varied between approximately 9-13 W/m2 degree C for fingers and palm and back of hand, respectively. Calculated heat losses showed significant individual variation, corresponding to the maintained skin to ambient temperature gradient. Individual values from about 50 to more than 300 W/m2 were calculated. Several subjects showed CIVD and heat fluxes associated with this phenomenon were sometimes doubled. The measurement results showed realistic and comparable with literature date. The advantages of the thermal hand model can be counted as easy to use; directly measures the heat loss; highly reproducible and no interruption. It appears that a heated hand model provides a useful methods for analysis and quantification of hand heat loss.

Entities:  

Mesh:

Year:  1999        PMID: 10510516     DOI: 10.2114/jpa.18.135

Source DB:  PubMed          Journal:  Appl Human Sci        ISSN: 1341-3473


  2 in total

1.  Thermal comfort range of a military cold protection glove: database by thermophysiological simulation.

Authors:  Carsten Zimmermann; Wolfgang H Uedelhoven; Bernhard Kurz; Karl Jochen Glitz
Journal:  Eur J Appl Physiol       Date:  2008-01-03       Impact factor: 3.078

Review 2.  Hands and feet: physiological insulators, radiators and evaporators.

Authors:  Nigel A S Taylor; Christiano A Machado-Moreira; Anne M J van den Heuvel; Joanne N Caldwell
Journal:  Eur J Appl Physiol       Date:  2014-07-11       Impact factor: 3.078

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.