Literature DB >> 10506374

[Effect of a crosslink or cerclage on the mechanical stability of an internal fixator].

L Bastian1, C Knop, U Lange, M Blauth.   

Abstract

This study was performed to evaluate the effect of a cerclage or a crosslink on internal fixator mechanical stability in an unstable spine injury model. Nine human thoracolumbar spine specimens were instrumented either with an internal fixator alone (T12-L2) or together with a cerclage or a crosslink. Four modes of loading were used: flexion, extension, lateral bending, and axial rotation. Moments itself were generated using a specially designed loading jig and loading system. The maximum moment applied was 10 Nm, three load-unload cycles were performed. The flexibility was measured by a motion tracker and range of motion (ROM), elastic zone (EZ) and neutral zone (NZ) were calculated. Statistical analysis was performed using the paired t-test (p < 0.05). For flexion, extension and lateral bending all devices were significantly more stable (p < 0.01), for axial rotation all devices were significantly less stable compared to the intact specimen (p < 0.01). But the crosslink provided significantly more stability compared to the internal fixator alone (p < 0.001). The complete device, i.e. internal fixator + crosslink, was significantly more stable compared to internal fixator + cerclage (p < 0.05). In this study the use of a cerclage had no additional effect in stabilizing the internal fixator. The operative and financial expenditure using a crosslink seems to be justified in fractures with a high rotationally instability, i.e. in type A-3-, B-, and C-injuries according to Magerl et al. [18].

Entities:  

Mesh:

Year:  1999        PMID: 10506374

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  4 in total

1.  Biomechanical analysis of a new expandable vertebral body replacement combined with a new polyaxial antero-lateral plate and/or pedicle screws and rods.

Authors:  Benjamin Ulmar; Stefanie Erhart; Stefan Unger; Kuno Weise; Werner Schmoelz
Journal:  Eur Spine J       Date:  2011-10-18       Impact factor: 3.134

2.  [Titanium vertebral body replacement of adjustable size. A prospective clinical trial].

Authors:  U Lange; S Edeling; C Knop; L Bastian; C Krettek; M Blauth
Journal:  Unfallchirurg       Date:  2006-09       Impact factor: 1.000

Review 3.  Cross-links in posterior pedicle screw-rod instrumentation of the spine: a systematic review on mechanical, biomechanical, numerical and clinical studies.

Authors:  Frédéric Cornaz; Jonas Widmer; Jess Gerrit Snedeker; José Miguel Spirig; Mazda Farshad
Journal:  Eur Spine J       Date:  2020-10-03       Impact factor: 3.134

4.  [Augmented posterior instrumentation for the treatment of osteoporotic vertebral body fractures].

Authors:  D Krappinger; T J Kastenberger; R Schmid
Journal:  Oper Orthop Traumatol       Date:  2012-02       Impact factor: 1.154

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.