Literature DB >> 10505389

Assessment of aortic pressure power components and their link to overall elastic and resistive arterial properties.

R Burattini1, K B Campbell.   

Abstract

This paper reviews the analytical expressions for in-phase and quadrature aortic power components associated with the real and imaginary parts of aortic input admittance, respectively. It is shown that active power Wact, and its steady, Wstdy, and pulsatile, Wpuls, components logically follow from in-phase power. Reactive power follows from quadrature power only for sinusoidal signals. The definition of reactive power indexes for real aortic pressures and flows requires extreme care. The link between overall arterial properties and pressure power components (and indexes) is investigated, making use of a three-element windkessel model and ascending aortic pressure and flow data taken from eight anaesthetised dogs, under basal state and after treatment with a vasoconstrictor (methoxamine). Seven dogs are normotensive in the baseline state (NBA cases, n = 7), the average (+/- SE) of mean pressure being 86.5 +/- 5.2 mmHg. The eighth dog has a baseline mean pressure of 134 mmHg and is considered to be hypertensive. The two experimental cases from this dog are grouped with those from the other seven dogs after vasoconstriction, to form the NVC + H group (n = 9). On average, fitting the model to the experimental data yields a 100% increase (p < 0.05) in total peripheral resistance, a 63% decrease (p < 0.01) in total arterial compliance and a 10% decrease (p > 0.05) in aortic characteristic impedance, from the NBA group to the NVC + H. Correspondingly, the peak-to-peak amplitude of quadrature power shows a 69% increase (p < 0.02). Wact, Wstdy, and Wpuls show a 28% increase (p > 0.05), a 40% increase (p < 0.02) and a 43% decrease (p > 0.05), respectively. Energetic efficiency of the arterial system, Eart = 1 - (Wpuls/Wact), increases by 8% (p < 0.02). From analysis of the estimates of power components and arterial parameters in relation to low-frequency phase angles of aortic impedance, it is concluded that the decrease in total arterial compliance with increasing pressure reduces the power lost in pulsation. This happens at the expense of an increase in quadrature power and absolute values of related reactive power indexes.

Entities:  

Mesh:

Year:  1999        PMID: 10505389     DOI: 10.1007/BF02513314

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

Review 1.  Ventriculo-arterial coupling: concepts, assumptions, and applications.

Authors:  D A Kass; R P Kelly
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

2.  Two arterial effective reflecting sites may appear as one to the heart.

Authors:  R Burattini; G G Knowlen; K B Campbell
Journal:  Circ Res       Date:  1991-01       Impact factor: 17.367

3.  Determinants of systemic hydraulic power in unanesthetized dogs.

Authors:  R H Cox
Journal:  Am J Physiol       Date:  1974-03

4.  Optimal power generation by the left ventricle. A study in the anesthetized open thorax cat.

Authors:  G J van den Horn; N Westerhof; G Elzinga
Journal:  Circ Res       Date:  1985-02       Impact factor: 17.367

5.  Fourier analysis of left ventricular performance. Evaluation of impedance matching.

Authors:  F L Abel
Journal:  Circ Res       Date:  1971-02       Impact factor: 17.367

6.  Steady and pulsatile energy losses in the systemic circulation under normal conditions and in simulated arterial disease.

Authors:  M F O'Rourke
Journal:  Cardiovasc Res       Date:  1967-10       Impact factor: 10.787

7.  Use of Fourier series for the analysis of biological systems.

Authors:  E O Attinger; A Anné; D A McDonald
Journal:  Biophys J       Date:  1966-05       Impact factor: 4.033

8.  Ventricular/vascular interaction in patients with mild systemic hypertension and normal peripheral resistance.

Authors:  W W Nichols; M F O'Rourke; A P Avolio; T Yaginuma; C J Pepine; C R Conti
Journal:  Circulation       Date:  1986-09       Impact factor: 29.690

9.  Effects of vasoactive drugs upon haemodynamic power and input impedance in normal rats.

Authors:  G Wright
Journal:  Cardiovasc Res       Date:  1991-11       Impact factor: 10.787

10.  Input impedance of the systemic circulation in man.

Authors:  W W Nichols; C R Conti; W E Walker; W R Milnor
Journal:  Circ Res       Date:  1977-05       Impact factor: 17.367

View more
  1 in total

1.  Harmonic analysis of noninvasively recorded arterial pressure waveforms in healthy bonnet macaques (Macaca radiata).

Authors:  Oladipupo Olafiranye; Louis Salciccioli; Haroon Kamran; Mark Stewart; John Carter; Jason M Lazar
Journal:  J Am Assoc Lab Anim Sci       Date:  2011-01       Impact factor: 1.232

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.