Literature DB >> 10504642

Decreased cerebral emboli during distal aortic arch cannulation: a randomized clinical trial.

M A Borger1, R L Taylor, R D Weisel, G Kulkarni, M Benaroia, V Rao, G Cohen, L Fedorko, C M Feindel.   

Abstract

BACKGROUND: Cerebral emboli occur during cardiopulmonary bypass and are a principal cause of postoperative neurologic dysfunction. We hypothesized that arterial cannulation of the distal aortic arch, with placement of the cannula tip beyond the left subclavian artery, will result in fewer cerebral microemboli than conventional cannulation of the ascending aorta.
METHODS: Patients undergoing coronary bypass surgery with a single crossclamp technique were randomized to receive cannulation of the distal aortic arch (n = 17) or standard cannulation of the ascending aorta (control group, n = 17). Trendelenburg positioning was used whenever possible. Cerebral emboli were quantified by continuous transcranial Doppler monitoring of the middle cerebral artery.
RESULTS: Baseline demographics were similar for the 2 groups of patients, including cardiopulmonary bypass and crossclamp times. Cerebral microemboli were detected during cardiopulmonary bypass in all patients, with a range of 17 to 627 emboli. The total number of detected emboli was lower in the arch cannulation group (152 +/- 33, mean +/- standard error of the mean) than in the conventional cannulation group (249 +/- 35, P =.04). Embolization rates were lower in distal arch patients than in control patients during cardiopulmonary bypass (2.0 +/- 0.3 vs 4.2 +/- 0.9 per minute, respectively, P =.03). Reduction in cerebral emboli by distal arch cannulation was most pronounced during perfusionist interventions.
CONCLUSIONS: Cannulation of the distal aortic arch results in less cerebral microembolism than conventional cannulation of the ascending aorta. Provided it is performed safely, distal arch cannulation may be an important surgical option for patients with severe atherosclerosis of the ascending aorta.

Entities:  

Mesh:

Year:  1999        PMID: 10504642     DOI: 10.1016/S0022-5223(99)70021-8

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs.

Authors:  Timothy A Dickinson; Jeffrey B Riley; Jeffrey C Crowley; Paul M Zabetakis
Journal:  J Extra Corpor Technol       Date:  2006-09

2.  Incidence of Cerebral Microemboli in Single-Dose vs. Multidose Cardioplegia in Adult Cardiac Surgery.

Authors:  Laith Mukdad; William Toppen; Yas Sanaiha; Aditya Mantha; Stephanie Bland; Richard Shemin; Peyman Benharash
Journal:  J Extra Corpor Technol       Date:  2018-09

Review 3.  Shaggy and calcified aorta: surgical implications.

Authors:  Ikuo Fukuda; Kazuyuki Daitoku; Masahito Minakawa; Wakako Fukuda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-02-13

4.  Risk factors of atheromatous aorta in cardiovascular surgery.

Authors:  Fernando A Atik; Isaac Azevedo Silva; Claudio Ribeiro da Cunha
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Oct-Dec

5.  Proximal aortic arch cannulation for proximal ascending aortic aneurysms.

Authors:  Bilgin Emrecan; Firat Durna; Serkan Girgin; Mohammed Alshalaldeh
Journal:  Kardiochir Torakochirurgia Pol       Date:  2014-06-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.