Literature DB >> 10504217

Self-referencing, non-invasive, ion selective electrode for single cell detection of trans-plasma membrane calcium flux.

P J Smith1, K Hammar, D M Porterfield, R H Sanger, J R Trimarchi.   

Abstract

Biological systems have very different internal ion compositions in comparison with their surrounding media. The difference is maintained by transport mechanisms across the plasma membrane and by internal stores. On the plasma membrane, we can classify these mechanisms into three types, pumps, porters, and channels. Channels have been extensively studied, particularly since the advent of the patch clamp technique, which opened new windows into ion channel selectivity and dynamics. Pumps, particularly the plasma membrane Ca(2+)-ATPase, and porters are more illusive. The technique described in this paper, the self-referencing, ion-selective (or Seris) probe, has the ability to monitor the behavior of membrane transport mechanisms, such as the pumps and porters, in near to real-time by non-invasively measuring local extracellular ion gradients with high sensitivity and square micron spatial resolution. The principles behind the self-referencing technique are described with an overview of systems utilizing ion, electrochemical and voltage sensors. Each of these sensors employs the simple expedient of increasing the system resolution by self-referencing and, thereby, removing the drift component inherent to all electrodes. The approach is described in detail, as is the manner in which differential voltage measurements can be converted into a flux value. For the calcium selective probes, we can resolve flux values in the low to sub pmol.cm(-2)s(-1) range. Complications in the use of the liquid ion exchange cocktail are discussed. Applications of the calcium selective probe are given, drawing on examples from the plant sciences, developmental biology, muscle physiology, and the neurosciences. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10504217     DOI: 10.1002/(SICI)1097-0029(19990915)46:6<398::AID-JEMT8>3.0.CO;2-H

Source DB:  PubMed          Journal:  Microsc Res Tech        ISSN: 1059-910X            Impact factor:   2.769


  38 in total

1.  Nerve injury induces a rapid efflux of nitric oxide (NO) detected with a novel NO microsensor.

Authors:  S M Kumar; D M Porterfield; K J Muller; P J Smith; C L Sahley
Journal:  J Neurosci       Date:  2001-01-01       Impact factor: 6.167

2.  Ion-selective self-referencing probes for measuring specific ion flux.

Authors:  Brian Reid; Min Zhao
Journal:  Commun Integr Biol       Date:  2011-09-01

3.  Electrical phenotypes of calcium transport mutant strains of a filamentous fungus, Neurospora crassa.

Authors:  Ahmed Hamam; Roger R Lew
Journal:  Eukaryot Cell       Date:  2012-03-09

4.  Specific ion fluxes generate cornea wound electric currents.

Authors:  Brian Reid; Ana Carolina Vieira; Lin Cao; Mark J Mannis; Ivan R Schwab; Min Zhao
Journal:  Commun Integr Biol       Date:  2011-07-01

5.  Modulating endogenous electric currents in human corneal wounds--a novel approach of bioelectric stimulation without electrodes.

Authors:  Brian Reid; Enrique O Graue-Hernandez; Mark J Mannis; Min Zhao
Journal:  Cornea       Date:  2011-03       Impact factor: 2.651

6.  Early, H+-V-ATPase-dependent proton flux is necessary for consistent left-right patterning of non-mammalian vertebrates.

Authors:  Dany S Adams; Kenneth R Robinson; Takahiro Fukumoto; Shipeng Yuan; R Craig Albertson; Pamela Yelick; Lindsay Kuo; Megan McSweeney; Michael Levin
Journal:  Development       Date:  2006-03-22       Impact factor: 6.868

7.  Role of a mitogen-activated protein kinase cascade in ion flux-mediated turgor regulation in fungi.

Authors:  Roger R Lew; Natalia N Levina; Lana Shabala; Marinela I Anderca; Sergey N Shabala
Journal:  Eukaryot Cell       Date:  2006-03

8.  Ion trapping with fast-response ion-selective microelectrodes enhances detection of extracellular ion channel gradients.

Authors:  Mark A Messerli; Leon P Collis; Peter J S Smith
Journal:  Biophys J       Date:  2009-02-18       Impact factor: 4.033

9.  Release and elementary mechanisms of nitric oxide in hair cells.

Authors:  Ping Lv; Adrian Rodriguez-Contreras; Hyo Jeong Kim; Jun Zhu; Dongguang Wei; Sihn Choong-Ryoul; Emily Eastwood; Karen Mu; Snezana Levic; Haitao Song; Petrov Y Yevgeniy; Peter J S Smith; Ebenezer N Yamoah
Journal:  J Neurophysiol       Date:  2010-03-10       Impact factor: 2.714

10.  Measurement of extracellular ion fluxes using the ion-selective self-referencing microelectrode technique.

Authors:  Guillaume Luxardi; Brian Reid; Fernando Ferreira; Pauline Maillard; Min Zhao
Journal:  J Vis Exp       Date:  2015-05-03       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.