Plateletpheresis efficiency: a comparison of the spectra LRS and AMICUS separators.

R J Benjamin1, P Rojas, S Christmas, J Neal, S Broughton, C Burgio, B Barrett, W H Churchill.   

Abstract

BACKGROUND: Optimizing the yields of plateletpheresis by increasing collection efficiencies may provide several benefits: to patients, by increasing the dose in single-donor platelet (SDP) units; to the collection center, by increasing the percentage of components that may be split into double units; and/or to the donor, by reducing the duration of donation. STUDY DESIGN AND METHODS: A prospective, randomized study was undertaken to compare the efficiency of platelet collection in paired donations by 21 donors on two cell separators (Spectra LRS, version [v] 5.1; and AMICUS, v2.37). The order of donation was randomly assigned; donations were performed at least 2 weeks apart. A fixed blood volume (4000 mL) was processed by utilizing standard protocols. Findings were confirmed in a retrospective, matched study that compared the two separators by using fixed collection times (90 min).
RESULTS: The AMICUS and Spectra LRS separators consistently produced white cell-reduced (<1 x 10(6) white cells) components. The AMICUS harvested 32 percent more platelets on average (median, 4.9 x 10(11); range, 1.5-8.7 x 10(11)) than the Spectra LRS (median, 3.7 x 10(11); range, 2.1-7.7 x 10(11)) (p = 0.03), with mean times of 71.5 and 66.0 minutes (p = 0.03), respectively, to process 4000 mL. Mild donor reactions tended to be more common on the AMICUS separator, which used significantly more ACD (median 482 mL vs. 389 mL; p<0.0001) than on the Spectra LRS.
CONCLUSIONS: The AMICUS separator harvested more platelets per unit of blood volume processed than the Spectra LRS. Possible benefits include increased dose in each single-donor unit, increased double-unit harvests, and/or shorter donation time.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10504127     DOI: 10.1046/j.1537-2995.1999.39080895.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  4 in total

1.  Pre- and post- donation haematological values in healthy donors undergoing plateletpheresis with five different systems.

Authors:  Sudipta Sekhar Das; Rajendra Chaudhary; Sunil Kumar Verma; Shashank Ojha; Dheeraj Khetan
Journal:  Blood Transfus       Date:  2009-07       Impact factor: 3.443

2.  Comparison of Plateletpheresis on the Fenwal Amicus and Fresenius Com.Tec Cell Separators.

Authors:  Fevzi Altuntas; Ismail Sari; Ismail Kocyigit; Leylagul Kaynar; Sibel Hacioglu; Ahmet Ozturk; Mehmet Oztekin; Musa Solmaz; Bulent Eser; Mustafa Cetin; Ali Unal
Journal:  Transfus Med Hemother       Date:  2008-09-16       Impact factor: 3.747

3.  Comparison of plateletpheresis on three continuous flow cell separators.

Authors:  Anita Tendulkar; Sunil B Rajadhyaksha
Journal:  Asian J Transfus Sci       Date:  2009-07

4.  Initial values of donor hematocrit and efficiency of plateletpheresis.

Authors:  Elvedin Landzo; Alma Sofo-Hafizovic; Vesna Cetkovic-Basic
Journal:  Acta Inform Med       Date:  2013
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.