Fluid dynamic characterization of operating conditions for continuous flow blood pumps.

Z J Wu1, J F Antaki, G W Burgreen, K C Butler, D C Thomas, B P Griffith.   

Abstract

As continuous flow pumps become more prominent as long-term ventricular assist devices, the wide range of conditions under which they must be operated has become evident. Designed to operate at a single, best-efficiency, operating point, continuous flow pumps are required to perform at off-design conditions quite frequently. The present study investigated the internal fluid dynamics within two representative rotary fluid pumps to characterize the quality of the flow field over a full range of operating conditions. A Nimbus/UoP axial flow blood pump and a small centrifugal pump were used as the study models. Full field visualization of flow features in the two pumps was conducted using a laser based fluorescent particle imaging technique. Experiments were performed under steady flow conditions. Flow patterns at inlet and outlet sections were visualized over a series of operating points. Flow features specific to each pump design were observed to exist under all operating conditions. At off-design conditions, an annular region of reverse flow was commonly observed within the inlet of the axial pump, while a small annulus of backflow in the inlet duct and a strong disturbed flow at the outlet tongue were observed for the centrifugal pump. These observations were correlated to a critical nondimensional flow coefficient. The creation of a "map" of flow behavior provides an additional, important criterion for determining favorable operating speed for rotary blood pumps. Many unfavorable flow features may be avoided by maintaining the flow coefficient above a characteristic critical coefficient for a particular pump, whereas the intrinsic deleterious flow features can only be minimized by design improvement. Broadening the operating range by raising the band between the critical flow coefficient and the designed flow coefficient, is also a worthy goal for design improvement.

Entities:  

Mesh:

Year:  1999        PMID: 10503623     DOI: 10.1097/00002480-199909000-00015

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  8 in total

1.  Evaluation of local gas exchange in a pulsating respiratory support catheter.

Authors:  Heide J Eash; Brian J Frankowski; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2005 Mar-Apr       Impact factor: 2.872

Review 2.  Recent advances in computational methodology for simulation of mechanical circulatory assist devices.

Authors:  Alison L Marsden; Yuri Bazilevs; Christopher C Long; Marek Behr
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2014-01-21

Review 3.  New Challenges in the Treatment of Patients With Left Ventricular Support: LVAD Thrombosis.

Authors:  Ann B Nguyen; Nir Uriel; Sirtaz Adatya
Journal:  Curr Heart Fail Rep       Date:  2016-12

4.  PediaFlow™ Maglev Ventricular Assist Device: A Prescriptive Design Approach.

Authors:  James F Antaki; Michael R Ricci; Josiah E Verkaik; Shaun T Snyder; Timothy M Maul; Jeongho Kim; Dave B Paden; Marina V Kameneva; Bradley E Paden; Peter D Wearden; Harvey S Borovetz
Journal:  Cardiovasc Eng       Date:  2010-03-01

5.  High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions.

Authors:  Fang Yang; Robert L Kormos; James F Antaki
Journal:  J Thorac Cardiovasc Surg       Date:  2015-06-30       Impact factor: 5.209

6.  A New Mathematical Numerical Model to Evaluate the Risk of Thrombosis in Three Clinical Ventricular Assist Devices.

Authors:  Yuan Li; Hongyu Wang; Yifeng Xi; Anqiang Sun; Xiaoyan Deng; Zengsheng Chen; Yubo Fan
Journal:  Bioengineering (Basel)       Date:  2022-05-27

7.  The importance of dQ/dt on the flow field in a turbodynamic pump with pulsatile flow.

Authors:  Fangjun Shu; Stijn Vandenberghe; James F Antaki
Journal:  Artif Organs       Date:  2009-09       Impact factor: 3.094

8.  Flow features and device-induced blood trauma in CF-VADs under a pulsatile blood flow condition: A CFD comparative study.

Authors:  Zengsheng Chen; Sofen K Jena; Guruprasad A Giridharan; Steven C Koenig; Mark S Slaughter; Bartley P Griffith; Zhongjun J Wu
Journal:  Int J Numer Method Biomed Eng       Date:  2017-10-06       Impact factor: 2.747

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.