Literature DB >> 10501056

Comparison of matched BOLD and FAIR 4.0T-fMRI with [15O]water PET brain volumes.

M R Zaini1, S C Strother, J R Anderson, J S Liow, U Kjems, C Tegeler, S G Kim.   

Abstract

Valid comparisons of functional activation volumes from fMRI and PET require accurate registration, matched spatial resolution, and if possible matched noise. We coregistered 4.0T-fMRI and PET volumes, using a series of linear and nonlinear transformations applied to the PET volumes. Because of the limited number of fMRI slices that were available, PET volumes were transformed to the fMRI space. Since 4.0T-fMRI and 4.0T-MRI volumes have significant spatial distortion due to magnet inhomogeneities, high resolution 1.5T-MRI volumes were nonlinearly transformed to 4.0T-MRI volumes as part of the transformation chain. The smoothing effects of these registration transformations were measured, in order to match the spatial resolution of the coregistered fMRI and PET volumes. Spatial resolution of the transformed PET volumes in the fMRI space was degraded by up to 60% due to the transformation process. Due to both the image acquisition characteristics and the coregistration process, the transformed PET volumes had a spatial resolution that was lower than that of tMRI. Therefore, significant smoothing of fMRI volumes was necessary to match their spatial resolution with that of the transformed PET volumes. Matching the spatial resolution of the fMRI volumes to those of the transformed PET volumes was achieved by matching the shape of their point spread functions. In order to do this, Gaussian kernels were employed to smooth the fMRI volumes. We were unable to simultaneously match the resolution and noise of fMRI and PET signals in the motor cortex. Activation maps derived from transformed PET and smoothed fMRI volumes were compared. Contralateral motor cortex was active in all modalities but there were large variations in the size of the activated region and its signal to noise ratio across BOLD, FAIR, and PET images within each subject. Nevertheless, the relative CBF changes measured by FAIR were consistent with those determined by PET.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10501056     DOI: 10.1118/1.598652

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Localized cerebral blood flow response at submillimeter columnar resolution.

Authors:  T Q Duong; D S Kim; K Uğurbil; S G Kim
Journal:  Proc Natl Acad Sci U S A       Date:  2001-08-28       Impact factor: 11.205

Review 2.  Perfusion MR imaging: evolution from initial development to functional studies.

Authors:  Seong-Gi Kim
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

3.  Evaluation of MRI models in the measurement of CMRO2 and its relationship with CBF.

Authors:  Ai-Ling Lin; Peter T Fox; Yihong Yang; Hanzhang Lu; Li-Hai Tan; Jia-Hong Gao
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

Review 4.  Magnetic resonance imaging of the retina.

Authors:  Timothy Q Duong; Eric R Muir
Journal:  Jpn J Ophthalmol       Date:  2009-09-08       Impact factor: 2.447

5.  Magnetic resonance imaging of the retina: A brief historical and future perspective.

Authors:  Timothy Q Duong
Journal:  Saudi J Ophthalmol       Date:  2011-01-26

Review 6.  Physiological basis and image processing in functional magnetic resonance imaging: neuronal and motor activity in brain.

Authors:  Rakesh Sharma; Avdhesh Sharma
Journal:  Biomed Eng Online       Date:  2004-05-05       Impact factor: 2.819

7.  Cerebral blood flow measurement using fMRI and PET: a cross-validation study.

Authors:  Jean J Chen; Marguerite Wieckowska; Ernst Meyer; G Bruce Pike
Journal:  Int J Biomed Imaging       Date:  2008
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.