Literature DB >> 10497936

Reversed-phase ion-pair chromatography coupled to electrospray ionisation mass spectrometry by on-line removal of the counter-ions.

B H Forngren1, J Samskog, S A Gustavsson, N Tyrefors, K E Markides, B Långström.   

Abstract

A strong anion-exchanger was used as a trapping column to perform on-line coupling of ion-pair chromatography with electrospray ionisation mass spectrometry. Ion-pairing reagents were used to retain polar analytes of low molecular mass away from the solvent front in reversed-phase LC. The trapping column enabled removal of the non-volatile counter-ions from the mobile phase prior to detection, so that the electrospray process could be performed with favourable ionisation conditions and without contamination of the interface. The efficiency of the trapping process was studied for 1-octanesulfonic acid and sodium dodecyl sulfate as ion-pairing reagents. Using this on-line trapping method, biopterin and guanidine could be retained with a k'>2 and detected by electrospray mass spectrometry with a stable signal.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10497936     DOI: 10.1016/s0021-9673(99)00526-9

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  A convenient online desalination tube coupled with mass spectrometry for the direct detection of iodinated contrast media in untreated human spent hemodialysates.

Authors:  Md Mahamodun Nabi; Takumi Sakamoto; Md Al Mamun; Ariful Islam; A S M Waliullah; Shuhei Aramaki; Md Mahmudul Hasan; Shingo Ema; Akihiko Kato; Yutaka Takahashi; Tomoaki Kahyo; Mitsutoshi Setou; Tomohito Sato
Journal:  PLoS One       Date:  2022-06-06       Impact factor: 3.752

2.  Separation of intermediates of iron-catalyzed dopamine oxidation reactions using reversed-phase ion-pairing chromatography coupled in tandem with UV-visible and ESI-MS detections.

Authors:  Lin Zhang; Gargey Yagnik; Dianlu Jiang; Shuyun Shi; Peter Chang; Feimeng Zhou
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2012-10-29       Impact factor: 3.205

3.  An interface for sensitive analysis of monoamine neurotransmitters by ion-pair chromatography-electrospray ionization-mass spectrometry with continuous online elimination of ion-pair reagents.

Authors:  Shuyun Shi; Binqing Zhao; Gargey Yagnik; Feimeng Zhou
Journal:  Anal Chem       Date:  2013-07-02       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.