Literature DB >> 10489825

The effect of patient technique and training on the accuracy of self-recorded peak expiratory flow.

P F Gannon1, J Belcher, C F Pantin, P S Burge.   

Abstract

The aim of the study was to investigate the difference between encouraged self-recorded peak expiratory flow (PEF) with unobserved readings and to investigate any long-term changes in PEF self-recording. Patients were trained in the PEF technique and asked to keep 2-hourly PEF records until the next clinic visit. The patients PEF were then rechecked at the second clinic visit by a series of two unobserved, an observed and an encouraged PEF measurement. A subgroup of patients were reassessed at a third clinic visit. Forty-one patients produced serial PEF readings. Significant differences between unobserved and encouraged PEF readings were detected; there was a mean decrement of 21 L x min(-1) and limits of agreements suggested that the decrement could be as high as 60 L x min(-1). Visual and statistical analysis of the serial PEF provided showed a consistent deterioration in PEF over the record in 54% and 39% of cases, respectively. No significant differences were found in the subgroup who attended a third clinic visit. The results suggest that significant inaccuracies in unobserved peak expiratory flow readings can occur between clinic visits and this can be reflected as a consistent deterioration in some. This should be kept in mind when interpreting self-recorded peak expiratory flow measurements. Re-evaluation at the third visit following the retraining effect of the second visit on peak expiratory flow technique appears to reduce inaccuracies. It is believed that peak expiratory flow technique should be reevaluated at each clinic visit.

Entities:  

Mesh:

Year:  1999        PMID: 10489825     DOI: 10.1034/j.1399-3003.1999.14a07.x

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  5 in total

1.  The quality of home spirometry in school children with asthma.

Authors:  D C Wensley; M Silverman
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

2.  Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma. Midlands Thoracic Society Research Group.

Authors:  P S Burge; C F Pantin; D T Newton; P F Gannon; P Bright; J Belcher; J McCoach; D R Baldwin; C B Burge
Journal:  Occup Environ Med       Date:  1999-11       Impact factor: 4.402

Review 3.  Usefulness of monitoring lung function in asthma.

Authors:  P L P Brand; R J Roorda
Journal:  Arch Dis Child       Date:  2003-11       Impact factor: 3.791

Review 4.  Occupational asthma: a review.

Authors:  L J Lombardo; J R Balmes
Journal:  Environ Health Perspect       Date:  2000-08       Impact factor: 9.031

Review 5.  Breath tests in respiratory and critical care medicine: from research to practice in current perspectives.

Authors:  Attapon Cheepsattayakorn; Ruangrong Cheepsattayakorn
Journal:  Biomed Res Int       Date:  2013-09-18       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.