Literature DB >> 10487939

Isotope dilution-gas chromatography/mass spectrometry and liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of triiodo-L-thyronine in serum.

L M Thienpont1, C Fierens, A P De Leenheer, L Przywara.   

Abstract

Isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS) and isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/MS/MS) methods have been developed for an determination of triiodothyronine (T3) in serum and their potential as candidate reference methods investigated. In both methods, (13)C(9)-T3 was used as internal standard. Sample pretreatment consisted of deproteinization, extraction and high performance liquid chromatography (HPLC) purification. Conversion of serum thyroxine (T4) to T3 was controlled by adding (13)C(6)-T4. For GC/MS, T3 and (13)C(9)-T3 were converted to the N,O-di-heptafluorobutyryl (HFB) methyl ester derivatives and monitored at m/z 844 and 853. For LC/MS with electrospray ionization, the transitions m/z 652/661 to 606/614 were monitored. For use of the methods as candidate reference methods, special attention was paid to the calibration and the measurement protocol (duplicate analysis of each sample on three occasions). Evaluation of the ID-GC/MS and ID-LC/MS/MS methods showed the absence of interference by reverse T3 and T4, a limit of detection of 100 pg (GC/MS) and 18 pg (LC/MS), a recovery of 100 +/- 1.5% (95% confidence interval) and good precision (the total coefficient of variation, n = 6, was typically 1.5%). In addition to the recovery study, the accuracy of the methods was proven by method comparison (ID-GC/MS vs. LC/MS/MS) on three sera, showing a maximum deviation of 1.1%. Finally, the ID-GC/MS method was applied for measurement of 10 different human sera with a T3 concentration range from 0.6 to 7.3 ng/mL. Copyright 1999 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10487939     DOI: 10.1002/(SICI)1097-0231(19991015)13:19<1924::AID-RCM734>3.0.CO;2-U

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry.

Authors:  Dongli Wang; Heather M Stapleton
Journal:  Anal Bioanal Chem       Date:  2010-05-01       Impact factor: 4.142

2.  Simultaneous quantification of T4, T3, rT3, 3,5-T2 and 3,3'-T2 in larval zebrafish (Danio rerio) as a model to study exposure to polychlorinated biphenyls.

Authors:  Xiaopeng Chen; Kyla M Walter; Galen W Miller; Pamela J Lein; Birgit Puschner
Journal:  Biomed Chromatogr       Date:  2018-01-29       Impact factor: 1.902

Review 3.  Thyroid hormone testing by tandem mass spectrometry.

Authors:  Offie P Soldin; Steven J Soldin
Journal:  Clin Biochem       Date:  2010-08-04       Impact factor: 3.281

4.  Isotope dilution tandem mass spectrometric method for T4/T3.

Authors:  Nadia Soukhova; Offie P Soldin; Steven J Soldin
Journal:  Clin Chim Acta       Date:  2004-05       Impact factor: 3.786

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.