Literature DB >> 10487903

Reliability of nerve conduction studies among active workers.

D F Salerno1, R A Werner, J W Albers, M P Becker, T J Armstrong, A Franzblau.   

Abstract

Nerve conduction studies play an important role in clinical practice and research. Given their widespread use, reliability of tests merits careful attention. We assessed interexaminer and intraexaminer reliability of median and ulnar sensory nerve measures of amplitude, onset latency, and peak latency. In a two-phase cross-sectional study, two examiners tested 158 workers. Reliability was assessed with intraclass correlations (ICC) and kappa statistics. Median nerve measures were more reliable (ICC range, 0.76 to 0.92) than ulnar measures (ICC range, 0.22 to 0.85). Ulnar-onset latencies had the worst reliability. The median-ulnar peak latency difference was a particularly stable measure (ICC range, 0.79 to 0.92). The median-ulnar peak latency difference had high interexaminer reliability (kappa range, 0.71 to 0.79) for normal tests defined by cut points of 0.8 ms and 0.5 ms. Intraexaminer reliability was higher with the 0.8-ms cut point (kappa = 0.90 and kappa = 0.85 for examiners 1 and 2, respectively). Rather than absolute cut points to describe normality, a more rational interpretation of results can be made with ordered categories or continuous measures. Copyright 1999 John Wiley & Sons, Inc.

Mesh:

Year:  1999        PMID: 10487903     DOI: 10.1002/(sici)1097-4598(199910)22:10<1372::aid-mus6>3.0.co;2-s

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  11 in total

1.  The Relationship between Nerve Conduction Study and Clinical Grading of Carpal Tunnel Syndrome.

Authors:  Praveen Kumar Srikanteswara; Janardhan D Cheluvaiah; Jagadish B Agadi; Karthik Nagaraj
Journal:  J Clin Diagn Res       Date:  2016-07-01

2.  A cross-sectional assessment of the ACGIH TLV for hand activity level.

Authors:  Alfred Franzblau; Thomas J Armstrong; Robert A Werner; Sheryl S Ulin
Journal:  J Occup Rehabil       Date:  2005-03

3.  Comparison of automated versus traditional nerve conduction study methods for median nerve testing in a general worker population.

Authors:  Ann Marie Dale; Folasade Agboola; Amber Yun; Angelique Zeringue; Muhammed T Al-Lozi; Bradley Evanoff
Journal:  PM R       Date:  2014-10-15       Impact factor: 2.298

4.  Agreement between clinical screening procedures for neuropathy in the feet.

Authors:  Yi Wang; Jaclyn M Goodrich; Robert Werner; Brenda Gillespie; Niladri Basu; Alfred Franzblau
Journal:  Muscle Nerve       Date:  2012-05       Impact factor: 3.217

5.  The effectiveness of post-offer pre-placement nerve conduction screening for carpal tunnel syndrome.

Authors:  Ann Marie Dale; Bethany T Gardner; Angelique Zeringue; Robert Werner; Alfred Franzblau; Bradley Evanoff
Journal:  J Occup Environ Med       Date:  2014-08       Impact factor: 2.162

6.  Relationship of estimated dietary intake of n-3 polyunsaturated fatty acids from fish with peripheral nerve function after adjusting for mercury exposure.

Authors:  Yi Wang; Jaclyn M Goodrich; Robert Werner; Brenda Gillespie; Niladri Basu; Alfred Franzblau
Journal:  Sci Total Environ       Date:  2013-03-26       Impact factor: 7.963

7.  Repeatability of nerve conduction measurements using automation.

Authors:  Xuan Kong; Eugene A Lesser; J Thomas Megerian; Shai N Gozani
Journal:  J Clin Monit Comput       Date:  2006-09-14       Impact factor: 2.502

8.  Utilization of nerve conduction studies for the diagnosis of polyneuropathy in patients with diabetes: a retrospective analysis of a large patient series.

Authors:  Xuan Kong; Eugene A Lesser; Frisso A Potts; Shai N Gozani
Journal:  J Diabetes Sci Technol       Date:  2008-03

9.  The effects of occupational exposure to chlorpyrifos on the peripheral nervous system: a prospective cohort study.

Authors:  J W Albers; D H Garabrant; S J Schweitzer; R P Garrison; R J Richardson; S Berent
Journal:  Occup Environ Med       Date:  2004-03       Impact factor: 4.402

10.  Repeatability of nerve conduction measurements derived entirely by computer methods.

Authors:  Xuan Kong; Eugene A Lesser; Shai N Gozani
Journal:  Biomed Eng Online       Date:  2009-11-06       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.