Literature DB >> 10487311

Peri-implant tissues at submerged and non-submerged titanium implants.

I Abrahamsson1, T Berglundh, I S Moon, J Lindhe.   

Abstract

The present experiment was performed to study the peri-implant tissue response to non-submerged (1-stage) and initially submerged (2-stage) implant installation procedures. 6 beagle dogs were used. All mandibular premolars and the 1st, 2nd and 3rd maxillary premolars were extracted. After 3 months of healing, 3 fixtures of the Astra Tech System were installed and submerged in the right (or the left) edentulous, premolar region in each of the 6 dogs. Radiographs were obtained immediately after fixture installation. In the radiographs, the distance between the abutment-fixture junction and the most "coronal" bone in contact with the implant surface was determined. 3 months later, abutments were connected to the initially submerged fixtures and another 3 fixtures of the same system were installed in the contralateral, edentulous premolar region. Abutments were, however, immediately connected to the newly-installed fixtures (non-submerged side; test side). The mucosal flaps were replaced, adjusted and sutured in such a way that the coronal portion of the abutments remained exposed in the oral cavity. A new set of radiographs were obtained from all 6 implant sites in each animal. A period of plaque control was initiated. Clinical examinations were performed and radiographs obtained from all implant sites after another 3 months and at the termination of the experiment. 9 months after the 1st fixture installation procedure, the animals were sacrificed, the mandibles were removed, and each implant region dissected. The most mesially-located implant sites were processed for ground sectioning. The remaining biopsies were processed and embedded in EPON. The histometric analysis included assessment of the vertical dimension of the marginal soft and mineralized peri-implant tissues. The ground sections were used for measurements describing (i) "bone to implant contact" and (ii) "bone density". It was observed that the mucosa and bone tissue that formed at implants placed in a non-submerged or a submerged procedure had many features in common. Thus, figures describing (i) the height of the mucosa, (ii) the length of the junctional epithelium and the height and quality of the zone of "connective tissue integration", (iii) the % of bone to implant contact as well as (iv) the density of the peri-implant bone, were similar in the submerged and the non-submerged groups. It is therefore suggested that a non-submerged (1-stage) installation technique may provide conditions for tissue integration that are similar to those obtained using a submerged (2-stage) approach.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10487311     DOI: 10.1034/j.1600-051x.1999.260907.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  10 in total

1.  Marginal bony changes in relation to different vertical positions of dental implants.

Authors:  Jung-Myung Yi; Jae-Kwan Lee; Heung-Sik Um; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

Review 2.  Epithelial integrins with special reference to oral epithelia.

Authors:  H Larjava; L Koivisto; L Häkkinen; J Heino
Journal:  J Dent Res       Date:  2011-03-25       Impact factor: 6.116

3.  Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

Authors:  Chong Huat Siar; Chooi Gait Toh; Georgios E Romanos; Kok Han Ng
Journal:  Clin Oral Investig       Date:  2014-11-21       Impact factor: 3.573

4.  Wound models for periodontal and bone regeneration: the role of biologic research.

Authors:  Anton Sculean; Iain L C Chapple; William V Giannobile
Journal:  Periodontol 2000       Date:  2015-06       Impact factor: 7.589

5.  Premature exposure of dental implant cover screws. A retrospective evaluation of risk factors and influence on marginal peri-implant bone level changes.

Authors:  Moritz Hertel; Yun-Chie Roh; Konrad Neumann; Frank Peter Strietzel
Journal:  Clin Oral Investig       Date:  2016-11-12       Impact factor: 3.573

6.  Histological and immunohistochemical analysis of initial and early subepithelial connective tissue attachment at chemically modified and conventional SLA titanium implants. A pilot study in dogs.

Authors:  Frank Schwarz; Monika Herten; Martin Sager; Marco Wieland; Michel Dard; Jürgen Becker
Journal:  Clin Oral Investig       Date:  2007-03-15       Impact factor: 3.573

7.  Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects.

Authors:  Hyun-Chang Lim; Ronald Ernst Jung; Christoph Hans Franz Hämmerle; Myong Ji Kim; Kyeong-Won Paeng; Ui-Won Jung; Daniel Stefan Thoma
Journal:  J Periodontal Implant Sci       Date:  2018-06-30       Impact factor: 2.614

8.  One-Piece Titanium Implants: Retrospective Case Series.

Authors:  Gunar Wagner; Dieter Hartung
Journal:  Case Rep Dent       Date:  2021-04-08

9.  Comparative evaluation of peri-implant tissues in definitive and repeated abutment replacements: A randomized clinical trial.

Authors:  Prachi Rajendra Rathi; Rajashri Abhay Kolte; Abhay Pandurang Kolte
Journal:  J Indian Soc Periodontol       Date:  2022-01-01

10.  The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants.

Authors:  Nasreen Hamudi; Eitan Barnea; Evgeny Weinberg; Amir Laviv; Eitan Mijiritsky; Shlomo Matalon; Liat Chaushu; Roni Kolerman
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

  10 in total