Literature DB >> 10486715

How to achieve higher repeatability and reproducibility in capillary electrophoresis.

T Faller1, H Engelhardt.   

Abstract

The influence of experimental parameters on precision of migration times and accuracy of integration has been studied. The repeatability of migration times strongly depends on the proper selection of the rinse steps between each run of a CE system. The rinse steps have to be optimized additionally with each separation system. This is especially important for systems providing an anodic electroosmotic flow. The errors introduced by the integration software were studied by transferring the same data sets to different commercial available integration softwares. A strategy for the transfer of raw data files between several softwares is described. By using systems with identical peak areas or with identical peak heights it could be shown that the newly introduced softwares can cope better with the leading or tailing peaks. The RSD of quantitation strongly depends on the signal-to-noise ratio. At S/N ratios larger than 35 no differences between the various softwares studied could be observed. At lower S/N ratios the newly released softwares are to be preferred.

Mesh:

Substances:

Year:  1999        PMID: 10486715     DOI: 10.1016/s0021-9673(99)00382-9

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Novel volumetric method for highly repeatable injection in microchip electrophoresis.

Authors:  Noel S Ha; Jimmy Ly; Jason Jones; Shilin Cheung; R Michael van Dam
Journal:  Anal Chim Acta       Date:  2017-06-19       Impact factor: 6.558

2.  Online capillary electrophoresis - mass spectrometry analysis of histatin-5 and its degradation products.

Authors:  Jared Lamp; Svetlana P Ikonomova; Amy J Karlsson; Qiangwei Xia; Yan Wang
Journal:  Analyst       Date:  2020-07-13       Impact factor: 4.616

3.  Improving repeatability of capillary electrophoresis-a critical comparison of ten different capillary inner surfaces and three criteria of peak identification.

Authors:  Paweł Mateusz Nowak; Michał Woźniakiewicz; Marta Gładysz; Magdalena Janus; Paweł Kościelniak
Journal:  Anal Bioanal Chem       Date:  2017-05-08       Impact factor: 4.142

4.  The First Online Capillary Electrophoresis-Microscale Thermophoresis (CE-MST) Method for the Analysis of Dynamic Equilibria-The Determination of the Acidity Constant of Fluorescein Isothiocyanate.

Authors:  Paweł Mateusz Nowak; Maria Klag; Gabriela Kózka; Małgorzata Gołąb; Michał Woźniakiewicz
Journal:  Molecules       Date:  2022-08-06       Impact factor: 4.927

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.