Literature DB >> 10485423

Synthetic protein treated versus heparin coated cardiopulmonary bypass surfaces: similar clinical results and minor biochemical differences.

G Wimmer-Greinecker1, G Matheis, S Martens, G Oremek, U Abdel-Rahman, A Moritz.   

Abstract

OBJECTIVE: Complications associated with cardiopulmonary bypass (CPB) have gained more attention due to increased interest in coronary artery bypass grafting without CPB. The impact of heparin coating of CPB circuits has been discussed controversially. The present study examines if the treatment of the oxygenator surface with a synthetic protein may serve as an alternative to a completely heparin coated circuit.
METHODS: Fifty-eight patients undergoing coronary artery bypass grafting with CPB were randomly assigned to completely heparin coated circuits or synthetic protein treated oxygenators in a double blind protocol, focussing on the inflammatory reaction resulting in membrane damage, coagulation changes and markers of cerebral injury or dysfunction. Treatment groups did not differ as to preoperative demographics, and intraoperative clinical data. Patients with any neurologic disease or risk factors for cerebral dysfunction were not included in the study.
RESULTS: Postoperative clinical data did not differ between groups. Both surface treatments resulted in similar coagulation activation, hyperfibrinolysis and disseminated intravascular coagulation. Platelet count displayed a difference in favour of the heparin coated group (P = 0.029). Increased leukocyte activation reflected by rising myeloperoxidase concentrations on CPB was present in both synthetic protein and heparin coating groups. Interleukins 6 and 8 reacted similarly, but interleukin 8 increased significantly more (P = 0.0061) at the end of surgery in patients treated with protein treated oxygenators. The same pattern was observed for complement activation as determined by total complement complex (P = 0.006). Both surface changes resulted in moderately increased S-100B protein and neuron specific enolase, without difference between groups. Both markers did not reach concentrations associated with clinical manifestation of cerebral injury.
CONCLUSIONS: These results in routine patients with short bypass time, imply that protein treated oxygenators are associated with a limited increase of biochemical markers similar to heparin coating. However, significantly lower interleukin 8 release and complement activation can be achieved by heparin coating. The protein treatment is a standard feature of the oxygenator examined in both groups. It is not associated with additional cost and therefore appropriate for use in routine patients.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10485423     DOI: 10.1016/s1010-7940(99)00143-8

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  5 in total

1.  Extracorporeal life support for management of refractory cardiac or respiratory failure: initial experience in a tertiary centre.

Authors:  Adriano Peris; Giovanni Cianchi; Simona Biondi; Manuela Bonizzoli; Andrea Pasquini; Massimo Bonacchi; Marco Ciapetti; Giovanni Zagli; Simona Bacci; Chiara Lazzeri; Pasquale Bernardo; Erminia Mascitelli; Guido Sani; Gian Franco Gensini
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2010-05-21       Impact factor: 2.953

2.  Poly-2-methoxyethylacrylate-coated bypass circuits reduce activation of coagulation system and inflammatory response in congenital cardiac surgery.

Authors:  Yasuyuki Suzuki; Kazuyuki Daitoku; Masahito Minakawa; Kozo Fukui; Ikuo Fukuda
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

Review 3.  S100 and S100β: biomarkers of cerebral damage in cardiac surgery with or without the use of cardiopulmonary bypass.

Authors:  Shi-Min Yuan
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Oct-Dec

4.  Effects of topical hypothermia on postoperative inflammatory markers in patients undergoing coronary artery bypass surgery.

Authors:  Murat Kadan; Gokhan Erol; Bilgehan Savas Oz; Mehmet Arslan
Journal:  Cardiovasc J Afr       Date:  2014 Mar-Apr       Impact factor: 1.167

Review 5.  Strategies to prevent intraoperative lung injury during cardiopulmonary bypass.

Authors:  Efstratios E Apostolakis; Efstratios N Koletsis; Nikolaos G Baikoussis; Stavros N Siminelakis; Georgios S Papadopoulos
Journal:  J Cardiothorac Surg       Date:  2010-01-11       Impact factor: 1.637

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.