Literature DB >> 10484556

Influence of upper airway shunt on total respiratory impedance in infants.

K N Desager1, M Cauberghs, J Naudts, K P van de Woestijne.   

Abstract

When input impedance is determined by means of the forced oscillation technique, part of the oscillatory flow measured at the mouth is lost in the motion of the upper airway wall acting as a shunt. This is avoided by applying the oscillations around the subject's head (head generator) rather than at the mouth (conventional technique). In seven wheezing infants, we compared both techniques to estimate the importance of the upper airway wall shunt impedance (Zuaw) for the interpretation of the conventional technique results. Computation of Zuaw required, in addition, estimation of nasal impedance values, which were drawn from previous measurements (K. N. Desager, M. Willemen, H. P. Van Bever, W. De Backer, and P. A. Vermeire. Pediatr. Pulmonol. 11: 1-7, 1991). Upper airway resistance and reactance at 12 Hz ranged from 40 to 120 and from 0 to -150 hPa. l(-1). s, respectively. Varying nasal impedance within the range observed in infants did not result in major changes in the estimates of Zuaw or lung impedance (ZL), the impedance of the respiratory system in parallel with Zuaw. The conventional technique underestimated ZL, depending on the value of Zuaw. The head generator technique slightly overestimated ZL, probably because the pressure gradient across the upper airway was not completely suppressed. Because of the need to enclose the head in a box (which is not required with the conventional technique), the head generator technique is difficult to perform in infants.

Entities:  

Mesh:

Year:  1999        PMID: 10484556     DOI: 10.1152/jappl.1999.87.3.902

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  5 in total

1.  Noninvasive high frequency oscillatory ventilation through nasal prongs: bench evaluation of efficacy and mechanics.

Authors:  Daniele De Luca; Virgilio P Carnielli; Giorgio Conti; Marco Piastra
Journal:  Intensive Care Med       Date:  2010-09-21       Impact factor: 17.440

2.  Nasal high-frequency oscillation ventilation in neonates: a survey in five European countries.

Authors:  Hendrik Stefan Fischer; Kajsa Bohlin; Christoph Bührer; Gerd Schmalisch; Malte Cremer; Irwin Reiss; Christoph Czernik
Journal:  Eur J Pediatr       Date:  2014-09-18       Impact factor: 3.183

Review 3.  Impulse oscillometry in the evaluation of diseases of the airways in children.

Authors:  Hirsh D Komarow; Ian A Myles; Ashraf Uzzaman; Dean D Metcalfe
Journal:  Ann Allergy Asthma Immunol       Date:  2011-01-06       Impact factor: 6.347

4.  Simplified oscillation method for assessing nasal obstruction non-invasively and under spontaneous ventilation: a pilot study.

Authors:  L N A Lemes; P L Melo
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

5.  Comparison Study of Airway Reactivity Outcomes due to a Pharmacologic Challenge Test: Impulse Oscillometry versus Least Mean Squared Analysis Techniques.

Authors:  Elena Rodriguez; Charrell M Bullard; Milena H Armani; Thomas L Miller; Thomas H Shaffer
Journal:  Pulm Med       Date:  2013-04-11
  5 in total