Literature DB >> 10481802

[Initial results of treatment with the new AO wrist joint arthrodesis plate].

M Sauerbier1, N M Kania, S Kluge, B Bickert, G Germann.   

Abstract

Although diagnosis and therapeutic options for post-traumatic, idiopathic, and degenerative wrist arthropathies have improved during recent years, total wrist fusion is still frequently regarded as a popular option of treatment. Fourty-one patients underwent wrist arthrodesis between May 1994 and April 1996 using the recently introduced new AO-plate after earlier wrist trauma or Kienböck's disease. Thirty-five patients were examined. The average follow-up time was 15 months. Hand function and active digital range of motion (ADROM) was assessed clinically, grip strength was measured using a Jamar-Dynamometer and the Dexter-Computer-System. Patient's daily activities and general postoperative quality of life were estimated with the new DASH-questionnaire. It can be concluded from our data, that the widely claimed complete pain relief after total wrist fusion does not match reality. Eighty percent of the patients complained about reduction of postoperative quality of life with impaired personal hygiene and functional deficits; however, the majority would undergo the procedure again. Seventy percent of the patients returned to their original occupation. The DASH-questionnaire proved to be a very useful and sensitive tool for evaluating the patient's problems at the upper extremity.

Entities:  

Mesh:

Year:  1999        PMID: 10481802     DOI: 10.1055/s-1999-13536

Source DB:  PubMed          Journal:  Handchir Mikrochir Plast Chir        ISSN: 0722-1819            Impact factor:   1.018


  6 in total

Review 1.  [(Partial) fusion of the wrist : Indications and surgical procedures].

Authors:  F Unglaub; M F Langer; J M Unglaub; M Sauerbier; L P Müller; H Krimmer; P Hahn; C K Spies
Journal:  Unfallchirurg       Date:  2017-06       Impact factor: 1.000

2.  [Operative options for rectification after failed osteosynthesis of the distal radius].

Authors:  M Lautenbach; M Millrose; A Eisenschenk
Journal:  Orthopade       Date:  2014-04       Impact factor: 1.087

3.  Low-profile locking-plate vs. the conventional AO system: early comparative results in wrist arthrodesis.

Authors:  J F Hernekamp; P Schönle; T Kremer; U Kneser; B Bickert
Journal:  Arch Orthop Trauma Surg       Date:  2019-12-06       Impact factor: 3.067

Review 4.  [Wrist arthrodesis with a fixed-angle, "low-profile" fusion plate without carpometacarpal joint fixation].

Authors:  S Köhler; K Koch; A Arsalan-Werner; I M Mehling; J Seegmüller; H Krimmer; Michael Sauerbier
Journal:  Oper Orthop Traumatol       Date:  2017-09-12       Impact factor: 1.154

5.  [Total wrist fusion using the AO wrist fusion plate].

Authors:  Karlheinz Kalb; Karl-Josef Prommersberger
Journal:  Oper Orthop Traumatol       Date:  2009-11       Impact factor: 1.154

6.  [Clinical functional assessment of various surgical hand arthrodesis techniques].

Authors:  P Gonser; A Greiner; A Nusche; H-E Schaller; P Jaminet
Journal:  Orthopade       Date:  2013-11       Impact factor: 1.087

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.