S D O'Broin1, E W Gunter. 1. Department of Haematology, St James's Hospital, Dublin, Ireland. nutrition@stjames.ie
Abstract
BACKGROUND: Dried blood spots (DBS) on filter paper have been a successful and economical matrix for neonatal screening. OBJECTIVE: Our objective was to develop and evaluate an optimized method for DBS folate analysis and to assess DBS folate stability. DESIGN: DBS were eluted from paper by sonication in 5 g ascorbic acid/L containing 0.1% (by vol) Triton X-100 and hemoglobin folate values (HF; as pmol/g) were calculated from DBS eluate folate and hemoglobin concentrations. RESULTS: Over 95% of DBS folate was eluted during a standardized sonication cycle and DBS folate assay reproducibility was acceptable both within (CV: <8%) and between (CV: <9%) runs. HF means (+/-1 SD) from finger-stick DBS and conventional venous methods were 2513 +/- 1144 and 2607 +/- 1195 pmol/g, respectively, in blood samples taken concurrently from 80 donors, and they correlated well (r = 0.97, P < 0.001). HF values and erythrocyte folate measures may be interconverted by using the mean cell hemoglobin concentration. CONCLUSION: The DBS matrix has potential as an inexpensive and practical option for folate screening studies.
BACKGROUND: Dried blood spots (DBS) on filter paper have been a successful and economical matrix for neonatal screening. OBJECTIVE: Our objective was to develop and evaluate an optimized method for DBS folate analysis and to assess DBS folate stability. DESIGN:DBS were eluted from paper by sonication in 5 g ascorbic acid/L containing 0.1% (by vol) Triton X-100 and hemoglobin folate values (HF; as pmol/g) were calculated from DBS eluate folate and hemoglobin concentrations. RESULTS: Over 95% of DBS folate was eluted during a standardized sonication cycle and DBS folate assay reproducibility was acceptable both within (CV: <8%) and between (CV: <9%) runs. HF means (+/-1 SD) from finger-stick DBS and conventional venous methods were 2513 +/- 1144 and 2607 +/- 1195 pmol/g, respectively, in blood samples taken concurrently from 80 donors, and they correlated well (r = 0.97, P < 0.001). HF values and erythrocyte folate measures may be interconverted by using the mean cell hemoglobin concentration. CONCLUSION: The DBS matrix has potential as an inexpensive and practical option for folate screening studies.
Authors: Z Z Nurgalieva; R Almuchambetova; A Machmudova; D Kapsultanova; M S Osato; J Peacock; R P Zoltek; P A Marchildon; D Y Graham; A Zhangabylov Journal: Clin Diagn Lab Immunol Date: 2000-11
Authors: Kobus Herbst; Matthew Law; Pascal Geldsetzer; Frank Tanser; Guy Harling; Till Bärnighausen Journal: Curr Opin HIV AIDS Date: 2015-11 Impact factor: 4.283
Authors: Jinkook Lee; Mark E McGovern; David E Bloom; P Arokiasamy; Arun Risbud; Jennifer O'Brien; Varsha Kale; Peifeng Hu Journal: Econ Hum Biol Date: 2015-09-11 Impact factor: 2.184
Authors: William E Funk; Suramya Waidyanatha; Shu H Chaing; Stephen M Rappaport Journal: Cancer Epidemiol Biomarkers Prev Date: 2008-08 Impact factor: 4.254