Literature DB >> 10476518

Endophthalmitis after phakic intraocular lens implantation to correct high myopia.

J J Pérez-Santonja1, J M Ruíz-Moreno, F de la Hoz, C Giner-Gorriti, J L Alió.   

Abstract

A 36-year-old woman had uneventful implantation of an angle-supported anterior chamber phakic intraocular lens (IOL) to correct high myopia. On the first postoperative day, she developed infectious endophthalmitis likely associated with intraoperative contamination. Group B beta-hemolytic Streptococcus endophthalmitis was confirmed by microbiologic studies. To our knowledge, this is the first documented case of infectious endophthalmitis after anterior chamber phakic IOL implantation to correct high myopia.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10476518     DOI: 10.1016/s0886-3350(99)00162-5

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

1.  Correction of high myopia with different phakic anterior chamber intraocular lenses: ICARE angle-supported lens and Verisyse iris-claw lens.

Authors:  Stanislawa Gierek-Ciaciura; Ariadna Gierek-Lapinska; Krzysztof Ochalik; Ewa Mrukwa-Kominek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07-01       Impact factor: 3.117

2.  Successful re-implantation of implantable collamer lens after management of post-ICL methicillin-resistant Staphylococcus epidermidis endophthalmitis.

Authors:  Manpreet Kaur; Jeewan S Titiyal; Namrata Sharma; Rohan Chawla
Journal:  BMJ Case Rep       Date:  2015-11-24
  2 in total