Use of biochemical markers in acute coronary syndromes. IFCC Scientific Division, Committee on Standardization of Markers of Cardiac Damage. International Federation of Clinical Chemistry.

M Panteghini1, F S Apple, R H Christenson, F Dati, J Mair, A H Wu.   

Abstract

This paper presents evidence and suggestions from the IFCC Committee on "Standardization of Markers of Cardiac Damage" (C-SMCD) on the use of biochemical markers for the triage diagnosis of acute coronary syndromes. There is general agreement that both 'early' and 'definitive' biochemical markers of myocardial damage are necessary and that these assays must be available with a turnaround time of 1 h or less. Currently, myoglobin is the marker that most effectively fits the role as an 'early' marker, whereas 'definitive' markers are cardiac troponins. Since the sensitivity of the initial electrocardiogram is only 50% for detecting myocardial infarction, the use of biochemical markers may significantly contribute to the early diagnosis and become relevant when the electrocardiogram is not diagnostic. In addition, new sensitive biochemical markers, particularly the cardiac troponins, are presently the best to detect the presence of minor myocardial cell damage. With regard to this, two decision limits are probably needed for the optimal use of troponins: a low abnormal value suggesting the presence of myocardial damage and a higher value suggesting the diagnosis of myocardial infarction according to traditionally used criteria. Properly designed studies should be performed to establish limits for each commercially available troponin assay. Finally, it is recognized that there is no need for the use of any biochemical marker when the clinical diagnosis is unequivocal, other than for diagnosing reinfarction, estimating the infarct size, and monitoring thrombolytic therapy.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10475079     DOI: 10.1515/CCLM.1999.107

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  14 in total

1.  Rapid and Sensitive Detection of Troponin I-T-C Complex from Human Serum using Microwave-Accelerated Metal-Enhanced Fluorescence.

Authors:  Kadir Aslan
Journal:  Nano Biomed Eng       Date:  2011

Review 2.  Plasmonic technology: novel approach to ultrasensitive immunoassays.

Authors:  Joseph R Lakowicz; Joanna Malicka; Evgenia Matveeva; Ignacy Gryczynski; Zygmunt Gryczynski
Journal:  Clin Chem       Date:  2005-07-28       Impact factor: 8.327

3.  Microwave-accelerated metal-enhanced fluorescence (MAMEF): application to ultra fast and sensitive clinical assays.

Authors:  Kadir Aslan; Chris D Geddes
Journal:  J Fluoresc       Date:  2005-12-22       Impact factor: 2.217

4.  Comparative study of cardiac troponin I and T measurements in a routine extra-cardiological clinical setting.

Authors:  F Pagani; G Bonetti; M Panteghini
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

5.  Acute coronary syndromes: Troponin triumphant?

Authors:  Paul O Collinson
Journal:  Nat Rev Cardiol       Date:  2009-12       Impact factor: 32.419

6.  Mean platelet volume in patients with acute coronary syndromes: a supportive diagnostic predictor.

Authors:  Randheer Pal; Rajeev Bagarhatta; Sandhya Gulati; Monika Rathore; Nidhi Sharma
Journal:  J Clin Diagn Res       Date:  2014-08-20

Review 7.  Cardiac markers in the diagnosis of acute coronary syndromes.

Authors:  P O Collinson; L Chamberlain
Journal:  Curr Cardiol Rep       Date:  2001-07       Impact factor: 2.931

8.  Cardio-protective effects of Corocalm on acute myocardial ischemia/reperfusion injury in rats.

Authors:  Jian-xun Liu; Xin-zhi Li; Xiao-bin Ma; Cheng-ren Lin; Yang-hui Wang; Xue-ying Ma; Min Wang
Journal:  Chin J Integr Med       Date:  2006-09       Impact factor: 1.978

9.  Myoglobin immunoassay utilizing directional surface plasmon-coupled emission.

Authors:  Evgenia Matveeva; Zygmunt Gryczynski; Ignacy Gryczynski; Joanna Malicka; Joseph R Lakowicz
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

10.  Effects of Corocalm (shuguan capsule) on acute myocardial ischemia in anesthetized dogs.

Authors:  Jian-xun Liu; Xin-zhi Li; Wei-hong Cong; Jian-hua Fu; Xiao-hong Shang
Journal:  Chin J Integr Med       Date:  2007-09       Impact factor: 1.978

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.