Literature DB >> 10474491

Reliability of radiological measurements in the assessment of hip dysplasia in adults.

M Nelitz1, K P Guenther, S Gunkel, W Puhl.   

Abstract

Radiographic measurements are commonly used to quantify the treatment results of hip dysplasia and assess further need of operative treatment. We investigated the interobserver and intraobserver reliability of the commonest radiographic techniques in the assessment of hip dysplasia in skeletally mature adults. Three observers independently analysed 100 hip radiographs of patients with hip dysplasia aged between 16 and 32 years. We measured centre-edge angle of Wiberg, acetabular angle of Sharp, acetabular index of the weightbearing zone, acetabular index of depth to width, ACM-angle, MZ-distance, acetabular head index, lateral subluxation and neck-shaft angle. In addition, the radiographs were reviewed a second time 3 months apart by two of the observers to assess intraobserver reliability. We found a high correlation (intraclass correlation coefficient) for interobserver reliability (0.76-0.87) and intraobserver reliability (0.70-0.92) for all radiographic measurements except acetabular index of depth to width, ACM-angle and MZ-distance. Depending on the clinical question we therefore recommend the use of one of the reliable measurements to assess the radiograph of a dysplastic hip.

Entities:  

Mesh:

Year:  1999        PMID: 10474491     DOI: 10.1259/bjr.72.856.10474491

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  49 in total

1.  Reliability and agreement of measures used in radiographic evaluation of the adult hip.

Authors:  Nicholas H Mast; Franco Impellizzeri; Stephan Keller; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2010-07-02       Impact factor: 4.176

Review 2.  The femoral neck-shaft angle on plain radiographs: a systematic review.

Authors:  Christoph Kolja Boese; Jens Dargel; Johannes Oppermann; Peer Eysel; Max Joseph Scheyerer; Jan Bredow; Philipp Lechler
Journal:  Skeletal Radiol       Date:  2015-08-25       Impact factor: 2.199

3.  The neck shaft angle: CT reference values of 800 adult hips.

Authors:  Christoph Kolja Boese; Janine Jostmeier; Johannes Oppermann; Jens Dargel; De-Hua Chang; Peer Eysel; Philipp Lechler
Journal:  Skeletal Radiol       Date:  2015-12-23       Impact factor: 2.199

4.  Chiari pelvic osteotomy in the treatment of adolescent hip disorders: possibilities, limitations and complications.

Authors:  Zoran Vukasinovic; Dusko Spasovski; Nemanja Slavkovic; Zoran Bascarevic; Zorica Zivkovic; Branislav Starcevic
Journal:  Int Orthop       Date:  2010-09-28       Impact factor: 3.075

5.  Radiographic evaluation of the hip has limited reliability.

Authors:  John C Clohisy; John C Carlisle; Robert Trousdale; Young-Jo Kim; Paul E Beaule; Patrick Morgan; Karen Steger-May; Perry L Schoenecker; Michael Millis
Journal:  Clin Orthop Relat Res       Date:  2008-12-02       Impact factor: 4.176

6.  A systematic approach to the plain radiographic evaluation of the young adult hip.

Authors:  John C Clohisy; John C Carlisle; Paul E Beaulé; Young-Jo Kim; Robert T Trousdale; Rafael J Sierra; Michael Leunig; Perry L Schoenecker; Michael B Millis
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

7.  Reliability of plain radiographic parameters for developmental dysplasia of the hip in children.

Authors:  Vidyadhar V Upasani; James D Bomar; Gaurav Parikh; Harish Hosalkar
Journal:  J Child Orthop       Date:  2012-05-26       Impact factor: 1.548

8.  Novel clinical and radiological measures of lower limb obesity.

Authors:  Harold Akehurst; Sebastien Crosswell; David Maska; Renata Bartucz; Sandeep Deo
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-01-23

9.  Interobserver repeatability of measurements on computed tomography images of lax canine hip joints from youth to maturity.

Authors:  Mandi J Lopez; Kechia M Davis; Susan L Jeffrey-Borger; Mark D Markel; Christy Rettenmund
Journal:  Vet Surg       Date:  2009-12       Impact factor: 1.495

10.  Operative Fluoroscopic Correction Is Reliable and Correlates With Postoperative Radiographic Correction in Periacetabular Osteotomy.

Authors:  James D Wylie; Jeremy A Ross; Jill A Erickson; Mike B Anderson; Christopher L Peters
Journal:  Clin Orthop Relat Res       Date:  2017-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.