Literature DB >> 10474099

Comparison of load transmission and bracket deformation between titanium and stainless steel brackets.

R Kapur1, P K Sinha, R S Nanda.   

Abstract

This study measures the load transmitted and structural integrity of stainless steel and titanium brackets on application of torsional forces. Both 0.018 and 0.022 inch slot size edgewise brackets were tested in a specially designed apparatus that applied a torque value of 45 degrees. The load generated was measured by an Instron Universal Testing Machine at intervals of 15 degrees, 30 degrees, and 45 degrees of torque application. The structural stability of the brackets was evaluated by measuring the bracket slot width with a traveling stereoscopic microscope before and after the brackets were subjected to torsional forces. The specimen population was composed of 80 brackets and 80 wire specimens. An independent sample t test was used for comparison of mean load generated at 45 degrees of torque application. Repeated measures ANOVA (one-way) comparison was used to evaluate changes in load at different torque levels for the stainless steel and titanium brackets. A paired t test (two-tail) was used to determine the difference between initial and final bracket slot width at 45 degrees of torque applied for the two bracket types. The titanium brackets transmitted higher loads at 15 degrees and 30 degrees torque and lower load at 45 degrees torque on application of torsional forces in comparison to stainless steel brackets. The titanium brackets demonstrated superior dimensional stability compared to stainless steel brackets (P < .0001).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10474099     DOI: 10.1016/s0889-5406(99)70238-6

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  5 in total

1.  Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.

Authors:  Ryan A Lacoursiere; David S Nobes; Darren L N Homeniuk; Jason P Carey; Hisham H Badawi; Paul W Major
Journal:  J Dent Biomech       Date:  2009-12-13

2.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

3.  Comparative study of torque expression among active and passive self-ligating and conventional brackets.

Authors:  Érika Mendonça Fernandes Franco; Fabrício Pinelli Valarelli; João Batista Fernandes; Rodrigo Hermont Cançado; Karina Maria Salvatore de Freitas
Journal:  Dental Press J Orthod       Date:  2015 Nov-Dec

4.  Impact of different rectangular wires on torsional expression of different sizes of buccal tube.

Authors:  Shabnam Ajami; Afshar-Rasti Boroujeni
Journal:  J Clin Exp Dent       Date:  2018-01-01

5.  Three-dimensional deformation of orthodontic brackets.

Authors:  Garrett W Melenka; David S Nobes; Paul W Major; Jason P Carey
Journal:  J Dent Biomech       Date:  2013-06-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.