Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (II) modeling oxygen diffusion.

S J Hepworth1, M O Leach, S J Doran.   

Abstract

Oxygen contamination of a polyacrylamide gel (PAG) dosimeter can have a significant detrimental effect upon the performance characteristics of the gel as a dosimeter. Oxygen contamination can occur during preparation, but can also arise from the diffusion of atmospheric oxygen through vessel walls. Even 'trace' amounts of oxygen present in any gaseous space (usually nitrogen filled) between the surface of the PAG and the vessel seal can have a detectable effect. This paper describes a method used to quantify the detrimental effects of a range of oxygen concentrations upon the performance of the PAG. The results of diffusion studies for air and pure oxygen diffusing into the PAG over time are presented and coupled with a novel method of calculating oxygen concentrations in the PAG. Results obtained suggest that the diffusion is Fickian. The coefficient of diffusion D has been calculated to be (8+/-2) x 10(-6) cm2 s(-1) for oxygen diffusing into PAG stored at 4 degrees C, under the assumption that the diffusion mechanism is independent of the concentration of the diffusing species. In addition, a quantitative relation has been established between the transverse relaxation rate R2 of the PAG and the concentration of oxygen present. The implications of these findings for polymer gel dosimetry are discussed.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10473201     DOI: 10.1088/0031-9155/44/8/302

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  Influencing Factors on Reproducibility and Stability of MRI NIPAM Polymer Gel Dosimeter.

Authors:  Farideh Pak; Alireza Farajollahi; Ali Movafaghi; Alireza Naseri
Journal:  Bioimpacts       Date:  2013-07-14

3.  Enzymatic Glucose Sensor Compensation for Variations in Ambient Oxygen Concentration.

Authors:  Bradley B Collier; Michael J McShane
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02

4.  CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume.

Authors:  C Audet; M Hilts; A Jirasek; C Duzenli
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

5.  The molecular mechanism of the anticancer effect of Artonin E in MDA-MB 231 triple negative breast cancer cells.

Authors:  Imaobong Christopher Etti; Rasedee Abdullah; Arifah Kadir; Najihah Mohd Hashim; Swee Keong Yeap; Mustapha Umar Imam; Faiqah Ramli; Ibrahim Malami; Kian Lim Lam; Ubong Etti; Peter Waziri; Marsitoh Rahman
Journal:  PLoS One       Date:  2017-08-03       Impact factor: 3.240

6.  Controlled molecular self-assembly of complex three-dimensional structures in soft materials.

Authors:  Changjin Huang; David Quinn; Subra Suresh; K Jimmy Hsia
Journal:  Proc Natl Acad Sci U S A       Date:  2017-12-18       Impact factor: 11.205

Review 7.  A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.

Authors:  Muhammad Zamir Mohyedin; Hafiz Mohd Zin; Mohd Zulfadli Adenan; Ahmad Taufek Abdul Rahman
Journal:  Polymers (Basel)       Date:  2022-07-16       Impact factor: 4.967

Review 8.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.