Literature DB >> 10469929

Injection-molding versus extrusion as manufacturing technique for the preparation of biodegradable implants.

A Rothen-Weinhold1, K Besseghir, E Vuaridel, E Sublet, N Oudry, F Kubel, R Gurny.   

Abstract

Polylactic acid (PLA) is a biocompatible and biodegradable material with wide utility for many applications, including the design of controlled-release systems for pharmaceutical agents. The factors determining the degradation kinetics of these systems include the composition and the molecular mass of the polymer, the morphology and the structure of the device, and the influence of thermal processes. The processing of the polymer determines the structure and design of the device, and influences to a high degree its morphology, namely its microporous structure, polymeric chain orientation and crystallinity.In this work, we aimed to compare the influence of two different implant manufacturing techniques, extrusion and injection-molding, on the in vitro degradation of the polymeric matrix. Both kinds of implants were loaded with a somatostatin analogue. Decrease in molecular weight, and polydispersity evolution during an accelerated in vitro degradation test were studied by size exclusion chromatography. Morphological changes in the polymeric matrix during degradation were followed after defined time intervals by means of scanning electron microscopy. Crystallinity studies were performed by differential scanning calorimetry and by X-ray analysis. Peptide stability in the polymeric matrix after both manufacturing methods was evaluated. Peptide release profiles, obtained in vitro during a week dissolution test, from both implant samples, were studied. It was shown that both molecular weight and polydispersity decreased after extrusion or injection-molding. This decrease was more pronounced with the latter technique. Crystallinity studies demonstrated that the crystalline network was not destroyed after both manufacturing methods. Peptide release profiles obtained in vitro were in good accordance with scanning electron microscopy. It was found that both manufacturing techniques had to be considered, although the extruded implants degraded more rapidly in vitro than the injection-molded ones.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10469929     DOI: 10.1016/s0939-6411(99)00034-x

Source DB:  PubMed          Journal:  Eur J Pharm Biopharm        ISSN: 0939-6411            Impact factor:   5.571


  5 in total

1.  Development of an indirect stereolithography technology for scaffold fabrication with a wide range of biomaterial selectivity.

Authors:  Hyun-Wook Kang; Dong-Woo Cho
Journal:  Tissue Eng Part C Methods       Date:  2012-04-27       Impact factor: 3.056

2.  A novel injection-molded capsular device for oral pulsatile delivery based on swellable/erodible polymers.

Authors:  Andrea Gazzaniga; Matteo Cerea; Alberto Cozzi; Anastasia Foppoli; Alessandra Maroni; Lucia Zema
Journal:  AAPS PharmSciTech       Date:  2011-01-26       Impact factor: 3.246

3.  Process-induced degradation of bioresorbable PDLGA in bone tissue scaffold production.

Authors:  H Little; E Themistou; S A Clarke; E Cunningham; F Buchanan
Journal:  J Mater Sci Mater Med       Date:  2017-12-28       Impact factor: 3.896

4.  Mechanical performance of graphenex/poly(ether ketone ketone) composite sheets by hot pressing.

Authors:  Q B Wang; D L Jia; X H Pei; X L Wu; F Xu; Z H Ye; H X Wang
Journal:  Sci Rep       Date:  2022-03-08       Impact factor: 4.379

5.  Thermoanalytical characterization of clindamycin-loaded intravitreal implants prepared by hot melt extrusion.

Authors:  Lana Tamaddon; Seyed Abolfazl Mostafavi; Reza Karkhane; Mohammad Riazi-Esfahani; Farid Abedin Dorkoosh; Morteza Rafiee-Tehrani
Journal:  Adv Biomed Res       Date:  2015-07-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.